Electrochemical Determination of B-Type Natriuretic Peptide with an Epitope-Imprinted Polymer-Based Sensor
Biosensors · 2024
DOI: 10.3390/bios14110533 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Kai-Hsi Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, National University of Kaohsiung, Kaohsiung 81148, Taiwan. Hauptthemen laut MEDLINE: Natriuretic Peptide, Brain, Polymers, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology of ROC, Zuoying Armed Forces General Hospital.
Abstract (Originalsprache)
B-type natriuretic peptides (BNP) are produced and secreted by the myocardium to reduce blood pressure and cardiac load. They cause vasodilation, natriuresis, growth suppression, and inhibition of the sympathetic nervous system and the renin–angiotensin–aldosterone system. The measurement of plasma BNP levels provides clinically useful information concerning the diagnosis and management of left ventricular dysfunction and heart failure, complementing other diagnostic testing procedures. In this work, three epitopes from the N-terminal (BNPnt), C-terminal (BNPct), and the cystine-bridged cyclic peptides (BNPr) of B-type natriuretic peptides were synthesized as templates for molecular imprinting. These peptides were doped into aniline (AN) and m-aminobenzenesulfonic acid (MSAN) for electropolymerization, thus forming epitope-imprinted poly(AN-co-MSAN) conductive films (EIPs). The monomer ratio was optimized using the electrochemical signals during polymerization. The optimized films were then characterized using a scanning electron microscope (SEM), atomic force microscope (AFM), and AC impedance. The electrochemical response of the films to the target peptides and to BNP was then measured. The sensing range of the EIPs-coated electrodes was from 0.001 to 1000 pg/mL for BNP. Finally, the BNP concentration in diluted serum samples was measured with the BNPrIP-coated electrode, giving 3.15 ± 0.07 pg/mL. By spiking the sample with known BNP concentrations, the accuracy was determined to be better than ±5%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical Engineering, National University of Kaohsiung, Kaohsiung 81148, Taiwan.
- Department of Internal Medicine, Division of Cardiology, Zuoying Armed Forces General Hospital, Kaohsiung 81342, Taiwan.
- Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM 87131, USA.
- Department of Chemical and Materials Engineering, National University of Kaohsiung, Kaohsiung 81148, Taiwan.
- Department of Materials Science and Engineering, I-Shou University, Kaohsiung 84001, Taiwan.
ORCID-Profile: James L Thomas
Förderung
- Ministry of Science and Technology of ROC
- Zuoying Armed Forces General Hospital
Zitieren
APA
Liu, K. H., Thomas, J. L., Chu, P. C., Ciou, J. C., Chen, C. Y., Lin, H. Y., & Lee, M. H. (2024). Electrochemical Determination of B-Type Natriuretic Peptide with an Epitope-Imprinted Polymer-Based Sensor. Biosensors. https://doi.org/10.3390/bios14110533
Vancouver
Liu KH, Thomas JL, Chu PC, Ciou JC, Chen CY, Lin HY, et al. Electrochemical Determination of B-Type Natriuretic Peptide with an Epitope-Imprinted Polymer-Based Sensor. Biosensors. 2024. doi:10.3390/bios14110533
BibTeX
@article{Liu2024,
author = {Liu, Kai-Hsi and Thomas, James L and Chu, Pei-Chia and Ciou, Jing-Chen and Chen, Chuen-Yau and Lin, Hung-Yin and Lee, Mei-Hwa},
title = {Electrochemical Determination of B-Type Natriuretic Peptide with an Epitope-Imprinted Polymer-Based Sensor},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14110533}
}
EUVIMED