A Machine Learning Assisted Non-Enzymatic Electrochemical Biosensor to Detect Urea Based on Multi-Walled Carbon Nanotube Functionalized with Copper Oxide Micro-Flowers

Jitendra B Zalke iD, Manish L Bhaiyya iD, Pooja A Jain, Devashree N Sakharkar, Jayu Kalambe, Nitin P Narkhede, Mangesh B Thakre, Dinesh R Rotake iD, Madhusudan B Kulkarni iD, Shiv Govind Singh

Biosensors · 15.10.2024 · 14 (10) · 504

DOI: 10.3390/bios14100504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 15.10.2024. Verfasst von Jitendra B Zalke und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics Engineering, Ramdeobaba University, Nagpur 440013, MH, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanotubes, Carbon, Urea, Copper. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detecting urea is crucial for diagnosing related health conditions and ensuring timely medical intervention. The addition of machine learning (ML) technologies has completely changed the field of biochemical sensing, providing enhanced accuracy and reliability. In the present work, an ML-assisted screen-printed, flexible, electrochemical, non-enzymatic biosensor was proposed to quantify urea concentrations. For the detection of urea, the biosensor was modified with a multi-walled carbon nanotube-zinc oxide (MWCNT-ZnO) nanocomposite functionalized with copper oxide (CuO) micro-flowers (MFs). Further, the CuO-MFs were synthesized using a standard sol-gel approach, and the obtained particles were subjected to various characterization techniques, including X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and Fourier transform infrared (FTIR) spectroscopy. The sensor’s performance for urea detection was evaluated by assessing the dependence of peak currents on analyte concentration using cyclic voltammetry (CV) at different scan rates of 50, 75, and 100 mV/s. The designed non-enzymatic biosensor showed an acceptable linear range of operation of 0.5–8 mM, and the limit of detection (LoD) observed was 78.479 nM, which is well aligned with the urea concentration found in human blood and exhibits a good sensitivity of 117.98 mA mM−1 cm−2. Additionally, different regression-based ML models were applied to determine CV parameters to predict urea concentrations experimentally. ML significantly improves the accuracy and reliability of screen-printed biosensors, enabling accurate predictions of urea levels. Finally, the combination of ML and biosensor design emphasizes not only the high sensitivity and accuracy of the sensor but also its potential for complex non-enzymatic urea detection applications. Future advancements in accurate biochemical sensing technologies are made possible by this strong and dependable methodology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesNanotubes, CarbonUreaCopperElectrochemical TechniquesMachine LearningHumansZinc OxideLimit of Detection

Stichwörter der Autor:innen

biomarkercopper oxide (CuO) micro-flowers (MFs)electrochemical detectionmachine learning (ML)non-enzymaticscreen-printed electrodes (SPEs)urea

Substanzen

Nanotubes, CarbonUreaCoppercuprous oxideZinc Oxide

Autor:innen und Institutionen

  • Department of Electronics Engineering, Ramdeobaba University, Nagpur 440013, MH, India.
  • Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Nagpur 440013, MH, India.
  • Department of Chemistry, D.R.B. Sindhu Mahavidhyalaya, Nagpur 440017, MH, India.
  • Department of Electrical Engineering, Indian Institute of Technology, Hyderabad 502284, TG, India.
  • Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA.
  • Department of Electronics and Communication Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education (MAHE), Manipal 576104, KA, India.

ORCID-Profile: Jitendra B Zalke, Manish L Bhaiyya, Dinesh R Rotake, Madhusudan B Kulkarni

Zitieren

APA

Zalke, J. B., Bhaiyya, M. L., Jain, P. A., Sakharkar, D. N., Kalambe, J., Narkhede, N. P., Thakre, M. B., Rotake, D. R., Kulkarni, M. B., & Singh, S. G. (2024). A Machine Learning Assisted Non-Enzymatic Electrochemical Biosensor to Detect Urea Based on Multi-Walled Carbon Nanotube Functionalized with Copper Oxide Micro-Flowers. Biosensors, 14(10), 504. https://doi.org/10.3390/bios14100504

Vancouver

Zalke JB, Bhaiyya ML, Jain PA, Sakharkar DN, Kalambe J, Narkhede NP, et al. A Machine Learning Assisted Non-Enzymatic Electrochemical Biosensor to Detect Urea Based on Multi-Walled Carbon Nanotube Functionalized with Copper Oxide Micro-Flowers. Biosensors. 2024;14(10):504. doi:10.3390/bios14100504

BibTeX
@article{Zalke2024,
  author = {Zalke, Jitendra B and Bhaiyya, Manish L and Jain, Pooja A and Sakharkar, Devashree N and Kalambe, Jayu and Narkhede, Nitin P and Thakre, Mangesh B and Rotake, Dinesh R and Kulkarni, Madhusudan B and Singh, Shiv Govind},
  title = {A Machine Learning Assisted Non-Enzymatic Electrochemical Biosensor to Detect Urea Based on Multi-Walled Carbon Nanotube Functionalized with Copper Oxide Micro-Flowers},
  journal = {Biosensors},
  year = {2024},
  volume = {14},
  number = {10},
  pages = {504},
  doi = {10.3390/bios14100504}
}
Kostenlos starten →