NIR-Sensitive Squaraine Dye—Peptide Conjugate for Trypsin Fluorogenic Detection
Biosensors · 2024
DOI: 10.3390/bios14100458 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Priyanka Balyan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Life Science and System Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu-Ku, Kitakyushu-Shi, Fukuoka 808-0196,…. Hauptthemen laut MEDLINE: Trypsin, Fluorescent Dyes, Peptides, Cyclobutanes. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Trypsin enzyme has gained recognition as a potential biomarker in several tumors, such as colorectal, gastric, and pancreatic cancer, highlighting its importance in disease diagnosis. In response to the demand for rapid, cost-effective, and real-time detection methods, we present an innovative strategy utilizing the design and synthesis of NIR-sensitive dye–peptide conjugate (SQ-3 PC) for the sensitive and selective monitoring of trypsin activity by fluorescence ON/OFF sensing. The current research deals with the design and synthesis of three unsymmetrical squaraine dyes SQ-1, SQ-2, and SQ-3 along with a dye–peptide conjugate SQ-3-PC as a trypsin-specific probe followed by their photophysical characterizations. The absorption spectral investigation conducted on both the dye alone and its corresponding dye–peptide conjugates in water, utilizing SQ-3 and SQ-3 PC respectively, reveals enhanced dye aggregation and pronounced fluorescence quenching compared to observations in DMSO solution. The absorption spectral investigation conducted on dye only and corresponding dye–peptide conjugates in water utilizing SQ-3 and SQ-3 PC, respectively, reveals not only the enhanced dye aggregation but also pronounced fluorescence quenching compared to that observed in the DMSO solution. The trypsin-specific probe SQ-3 PC demonstrated a fluorescence quenching efficiency of 61.8% in water attributed to the combined effect of aggregation-induced quenching (AIQ) and fluorescence resonance energy transfer (FRET). FRET was found to be dominant over AIQ. The trypsin-mediated hydrolysis of SQ-3 PC led to a rapid and efficient recovery of quenched fluorescence (5-fold increase in 30 min). Concentration-dependent changes in the fluorescence at the emission maximum of the dyes reveal that SQ-3 PC works as a trypsin enzyme-specific fluorescence biosensor with linearity up to 30 nM along with the limit of detection and limit of quantification of 1.07 nM and 3.25 nM, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Graduate School of Life Science and System Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu-Ku, Kitakyushu-Shi, Fukuoka 808-0196, Japan.
ORCID-Profile: Sai Kiran Mavileti, Shyam S Pandey, Tamaki Kato
Zitieren
APA
Balyan, P., Gupta, S., Mavileti, S. K., Pandey, S. S., & Kato, T. (2024). NIR-Sensitive Squaraine Dye—Peptide Conjugate for Trypsin Fluorogenic Detection. Biosensors. https://doi.org/10.3390/bios14100458
Vancouver
Balyan P, Gupta S, Mavileti SK, Pandey SS, Kato T. NIR-Sensitive Squaraine Dye—Peptide Conjugate for Trypsin Fluorogenic Detection. Biosensors. 2024. doi:10.3390/bios14100458
BibTeX
@article{Balyan2024,
author = {Balyan, Priyanka and Gupta, Shekhar and Mavileti, Sai Kiran and Pandey, Shyam S and Kato, Tamaki},
title = {NIR-Sensitive Squaraine Dye—Peptide Conjugate for Trypsin Fluorogenic Detection},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14100458}
}
EUVIMED