Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection
Biosensors · 18.09.2024 · 14 (9) · 445
DOI: 10.3390/bios14090445 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 18.09.2024. Verfasst von Shiva Akhtarian und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada. Hauptthemen laut MEDLINE: Biosensing Techniques, Dielectric Spectroscopy, Polymers, Escherichia coli. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council (NSERC), James and Joanne Love Chair in Environmental Engineering.
Abstract (Originalsprache)
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed to capture whole bacterial cells, especially when integrated into PoN microfluidic devices. However, improving the sensitivity and detection limits of these sensors remains challenging. In this study, we integrated CIP-functionalized stainless steel microwires (CIP-MWs) into a microfluidic device for the impedimetric detection of E. coli bacteria. The sensor featured two parallel microchannels with three-electrode configurations that allowed simultaneous control and electrochemical impedance spectroscopy (EIS) measurements. A CIP-MW and a non-imprinted polymer (NIP)-MW suspended perpendicular to the microchannels served as the working electrodes in the test and control channels, respectively. Electrochemical spectra were fitted with equivalent electrical circuits, and the charge transfer resistances of both cells were measured before and after incubation with target bacteria. The charge transfer resistance of the CIP-MWs after 30 min of incubation with bacteria was increased. By normalizing the change in charge transfer resistance and analyzing the dose–response curve for bacterial concentrations ranging from 0 to 107 CFU/mL, we determined the limits of detection and quantification as 2 × 102 CFU/mL and 1.4 × 104 CFU/mL, respectively. The sensor demonstrated a dynamic range of 102 to 107 CFU/mL, where bacterial counts were statistically distinguishable. The proposed sensor offers a sensitive, cost-effective, durable, and rapid solution for on-site identification of waterborne pathogens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, York University, Toronto, ON M3J 1P3, Canada.
- Department of Civil Engineering, York University, Toronto, ON M3J 1P3, Canada.
ORCID-Profile: Shiva Akhtarian, Pouya Rezai
Förderung
- Natural Sciences and Engineering Research Council (NSERC)
- James and Joanne Love Chair in Environmental Engineering
Zitieren
APA
Akhtarian, S., Kaur Brar, S., & Rezai, P. (2024). Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection. Biosensors, 14(9), 445. https://doi.org/10.3390/bios14090445
Vancouver
Akhtarian S, Kaur Brar S, Rezai P. Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection. Biosensors. 2024;14(9):445. doi:10.3390/bios14090445
BibTeX
@article{Akhtarian2024,
author = {Akhtarian, Shiva and Kaur Brar, Satinder and Rezai, Pouya},
title = {Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {9},
pages = {445},
doi = {10.3390/bios14090445}
}
EUVIMED