A Finger-Actuated Sample-Dosing Capillary-Driven Microfluidic Device for Loop-Mediated Isothermal Amplification
Biosensors · 2024
DOI: 10.3390/bios14090410 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Xuan Le und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroscience, School of Translational Medicine, Monash University, Melbourne, VIC 3004, Australia. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, SARS-CoV-2, Lab-On-A-Chip Devices, COVID-19. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHMRC Investigator Grant, Lord Mayor’s Charitable Foundation and the Ray William Houston Trust.
Abstract (Originalsprache)
Loop-mediated isothermal amplification (LAMP) has attracted significant attention for rapid and accurate point-of-care diagnostics. However, integrating sample introduction, lysis, amplification, and detection steps into an easy-to-use, disposable system has so far been challenging. This has limited the uptake of the technique in practical applications. In this study, we developed a colourimetric one-step LAMP assay that combines thermolysis and LAMP reaction, to detect the SARS-CoV-2 virus in nasopharyngeal swab samples from COVID-19-infected individuals. The limit of detection was 500 copies per reaction at 65 °C for 25 min in reaction tubes. Additionally, we developed a finger-operated capillary-driven microfluidic device with selective PVA coating. This finger-actuated microfluidic device could self-dose the required sample amount for the LAMP reaction and inhibit sample evaporation. Finally, we integrated the LAMP assay into the microfluidic device by short-term pre-storage of the LAMP master mix. Using this device, nasopharyngeal swab samples from COVID-19-infected individuals showed positive results at a reaction time of 35 min at 65 °C. This integrated device may be adapted to detect other RNA viruses of interest rapidly.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neuroscience, School of Translational Medicine, Monash University, Melbourne, VIC 3004, Australia.
- Dynamic Micro Devices Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
- Department of Infectious Disease, Alfred Hospital and School of Translational Medicine, Monash University, Melbourne, VIC 3004, Australia.
Förderung
- NHMRC Investigator Grant
- Lord Mayor’s Charitable Foundation and the Ray William Houston Trust
Zitieren
APA
Le, X., Chan, J., McMahon, J., Wisniewski, J. A., Coldham, A., Alan, T., & Kwan, P. (2024). A Finger-Actuated Sample-Dosing Capillary-Driven Microfluidic Device for Loop-Mediated Isothermal Amplification. Biosensors. https://doi.org/10.3390/bios14090410
Vancouver
Le X, Chan J, McMahon J, Wisniewski JA, Coldham A, Alan T, et al. A Finger-Actuated Sample-Dosing Capillary-Driven Microfluidic Device for Loop-Mediated Isothermal Amplification. Biosensors. 2024. doi:10.3390/bios14090410
BibTeX
@article{Le2024,
author = {Le, Xuan and Chan, Jianxiong and McMahon, James and Wisniewski, Jessica A and Coldham, Anna and Alan, Tuncay and Kwan, Patrick},
title = {A Finger-Actuated Sample-Dosing Capillary-Driven Microfluidic Device for Loop-Mediated Isothermal Amplification},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14090410}
}
EUVIMED