EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Electrochemical Biosensor for the Detection of Pulmonary Embolism and Myocardial Infarction

Yaw-Jen Chang, Fu-Yuan Siao iD, En-Yu Lin

Biosensors · 2024

DOI: 10.3390/bios14080386 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Yaw-Jen Chang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Chung Yuan Christian University, Chung Li District, Taoyuan City 320314, Taiwan. Hauptthemen laut MEDLINE: Biosensing Techniques, Pulmonary Embolism, Myocardial Infarction, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Changhua Christian Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the clinical similarities between pulmonary embolism (PE) and myocardial infarction (MI), physicians often encounter challenges in promptly distinguishing between them, potentially missing the critical window for the correct emergency response. This paper presents a biosensor, termed the PEMI biosensor, which is designed for the identification and quantitative detection of pulmonary embolism or myocardial infarction. The surface of the working electrode of the PEMI biosensor was modified with graphene oxide and silk fibroin to immobilize the mixture of antibodies. Linear sweep voltammetry was employed to measure the current-to-potential mapping of analytes, with the calculated curvature serving as a judgment index. Experimental results showed that the curvature exhibited a linear correlation with the concentration of antigen FVIII, and a linear inverse correlation with the concentration of antigen cTnI. Given that FVIII and cTnI coexist in humans, the upper and lower limits were determined from the curvatures of a set of normal concentrations of FVIII and cTnI. An analyte with a curvature exceeding the upper limit can be identified as pulmonary embolism, while a curvature falling below the lower limit indicates myocardial infarction. Additionally, the further the curvature deviates from the upper or lower limits, the more severe the condition. The PEMI biosensor can serve as an effective detection platform for physicians.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesPulmonary EmbolismMyocardial InfarctionElectrochemical TechniquesHumansGraphiteElectrodesTroponin I

Stichwörter der Autor:innen

cardiac troponin I (cTnI)factor VIII (FVIII)myocardial infarctionpulmonary embolismsilk fibroin (SF)

Substanzen

Graphitegraphene oxideTroponin I

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Chung Yuan Christian University, Chung Li District, Taoyuan City 320314, Taiwan.
  • Department of Emergency and Critical Care Medicine, Changhua Christian Hospital, Changhua 50006, Taiwan.

ORCID-Profile: Fu-Yuan Siao

Förderung

  • Changhua Christian Hospital

Zitieren

APA

Chang, Y. J., Siao, F. Y., & Lin, E. Y. (2024). An Electrochemical Biosensor for the Detection of Pulmonary Embolism and Myocardial Infarction. Biosensors. https://doi.org/10.3390/bios14080386

Vancouver

Chang YJ, Siao FY, Lin EY. An Electrochemical Biosensor for the Detection of Pulmonary Embolism and Myocardial Infarction. Biosensors. 2024. doi:10.3390/bios14080386

BibTeX
@article{Chang2024,
  author = {Chang, Yaw-Jen and Siao, Fu-Yuan and Lin, En-Yu},
  title = {An Electrochemical Biosensor for the Detection of Pulmonary Embolism and Myocardial Infarction},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14080386}
}
Kostenlos starten →