EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning

Minkyeong Choi iD, Eunji Lee iD, Seoyeon Park iD, Chae-Seung Lim iD, Woong-Sik Jang iD

Biosensors · 2024

DOI: 10.3390/bios14070348 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Minkyeong Choi und 4 weiteren Autor:innen. Beteiligte Einrichtung: BK21 Graduate Program, Department of Biomedical Sciences, College of Medicine, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of K…. Hauptthemen laut MEDLINE: SARS-CoV-2, Nucleic Acid Amplification Techniques, Point-of-Care Systems, COVID-19. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Korea Health Technology R&D Project, through the Korea Health Industry Development In-stitute, the National Research Foundation of Korea (NRF), funded by the Korean Government, MSIP, the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The COVID-19 pandemic has highlighted the urgent need for rapid and accurate diagnostic methods for various infectious diseases, including SARS-CoV-2. Traditional RT-PCR methods, while highly sensitive and specific, require complex equipment and skilled personnel. In response, we developed an integrated RT-LAMP-MS assay, which combines rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) with microscanning (MS) technology for detecting SARS-CoV-2. The assay uses magnesium pyrophosphate formed during LAMP amplification as a visual marker, allowing direct observation via microscopy without the need for additional chemical indicators or probes. For the SARS-CoV-2/IC RT-LAMP-MS assay, the sample-LAMP reagent mixture was added to a microchip with SARS-CoV-2 primers and internal controls, then incubated at 62 °C for 30 min in a heat block, followed by amplification analysis using a microscanner. In clinical tests, the RT-LAMP-MS assay showed 99% sensitivity and 100% specificity, which is identical to the RT-LAMP results and comparable to the commercial AllplexTM SARS-CoV-2 assay results. Additionally, the limit of detection (LOD) was determined to be 10−1 PFU mL−1 (dynamic range: 103~10−1 PFU mL−1). The assay delivers results in 30 min, uses low-cost equipment, and demonstrates 100% reproducibility in repeated tests, making it suitable for point-of-care use in resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2Nucleic Acid Amplification TechniquesPoint-of-Care SystemsCOVID-19Molecular Diagnostic TechniquesHumansSensitivity and SpecificityRNA, ViralCOVID-19 Nucleic Acid Testing

Stichwörter der Autor:innen

RT-LAMPSARS-CoV-2magnesium pyrophosphatepoint-of-care testingvisual detection

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • BK21 Graduate Program, Department of Biomedical Sciences, College of Medicine, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
  • Department of Laboratory Medicine, College of Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.
  • Emergency Medicine, College of Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.

ORCID-Profile: Minkyeong Choi, Eunji Lee, Seoyeon Park, Chae-Seung Lim, Woong-Sik Jang

Förderung

  • the Korea Health Technology R&D Project, through the Korea Health Industry Development In-stitute
  • the National Research Foundation of Korea (NRF), funded by the Korean Government, MSIP
  • the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education
  • Korea Health Technology R&D Project, through the Korea Health Industry Development Institute (KHIDI)
  • National Research Foundation of Korea (NRF), funded by the Korean Government, MSIP
  • Basic Science Research Program through the National Research Foundation of Korea (NRF)

Zitieren

APA

Choi, M., Lee, E., Park, S., Lim, C. S., & Jang, W. S. (2024). Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning. Biosensors. https://doi.org/10.3390/bios14070348

Vancouver

Choi M, Lee E, Park S, Lim CS, Jang WS. Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning. Biosensors. 2024. doi:10.3390/bios14070348

BibTeX
@article{Choi2024,
  author = {Choi, Minkyeong and Lee, Eunji and Park, Seoyeon and Lim, Chae-Seung and Jang, Woong-Sik},
  title = {Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14070348}
}
Kostenlos starten →