Fachartikel in der Zeitschrift Biosensors, online erschienen am 15.07.2024. Verfasst von Jianxia Lv und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Narcotics Laboratory Beijing Regional Center, Beijing 100164, China. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Gold, Platinum, Anti-Bacterial Agents. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the special scientific research project of School of Emergency Management, Jiangsu University, Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment, School of Emergency Management, Jiangsu University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Misusage of tetracycline (TC) antibiotics residue in animal food has posed a significant threat to human health. Therefore, there is an urgent need to develop highly sensitive and robust assays for detecting TC. In the current study, gold and platinum nanoparticles were deposited on carbon nanotubes (CNTs) through the superposition method (Au@Pt/CNTs-s) and one-pot method (Au@Pt/CNTs-o). Au@Pt/CNTs-s displayed higher enzyme-like activity than Au@Pt/CNTs-o, which were utilized for the development of sensitive magnetic immunoassays. Under the optimized conditions, the limits of detection (LODs) of magnetic immunoassays assisted by Au@Pt/CNTs-s and Au@Pt/CNTs-o against TCs could reach 0.74 ng/mL and 1.74 ng/m, respectively, which were improved 6-fold and 2.5-fold in comparison with conventional magnetic immunoassay. In addition, the measurement of TC-family antibiotics was implemented by this assay, and ascribed to the antibody used that could recognize TC, oxytetracycline, chlortetracycline, and doxycycline with high cross-reactivity. Furthermore, the method showed good accuracy (recoveries, 92.1–114.5% for milk; 88.6–92.4% for pork samples), which also were applied for determination of the targets in real samples. This study provides novel insights into the rapid detection of targets based on high-performance nanocatalysts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nanotubes, CarbonGoldPlatinumAnti-Bacterial AgentsMetal NanoparticlesTetracyclineImmunoassayAnimalsLimit of DetectionBiosensing TechniquesMilk

Stichwörter der Autor:innen

immunoassaynanozymerapid detectiontetracycline

Substanzen

Nanotubes, CarbonGoldPlatinumAnti-Bacterial AgentsTetracycline

Autor:innen und Institutionen

  • National Narcotics Laboratory Beijing Regional Center, Beijing 100164, China.
  • School of Emergency Management, Jiangsu University, Zhenjiang 212013, China.
  • School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China.

ORCID-Profile: Kun Zeng, Zhen Zhang

Förderung

  • the special scientific research project of School of Emergency Management, Jiangsu University
  • Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment
  • School of Emergency Management, Jiangsu University

Zitieren

APA

Lv, J., Huang, R., Zeng, K., & Zhang, Z. (2024). Magnetic Immunoassay Based on Au Pt Bimetallic Nanoparticles/Carbon Nanotube Hybrids for Sensitive Detection of Tetracycline Antibiotics. Biosensors, 14(7), 342. https://doi.org/10.3390/bios14070342

Vancouver

Lv J, Huang R, Zeng K, Zhang Z. Magnetic Immunoassay Based on Au Pt Bimetallic Nanoparticles/Carbon Nanotube Hybrids for Sensitive Detection of Tetracycline Antibiotics. Biosensors. 2024;14(7):342. doi:10.3390/bios14070342

BibTeX
@article{Lv2024,
  author = {Lv, Jianxia and Huang, Rui and Zeng, Kun and Zhang, Zhen},
  title = {Magnetic Immunoassay Based on Au Pt Bimetallic Nanoparticles/Carbon Nanotube Hybrids for Sensitive Detection of Tetracycline Antibiotics},
  journal = {Biosensors},
  year = {2024},
  volume = {14},
  number = {7},
  pages = {342},
  doi = {10.3390/bios14070342}
}
Kostenlos starten →