Challenges and Advances in Biomarker Detection for Rapid and Accurate Sepsis Diagnosis: An Electrochemical Approach
Biosensors · 17.06.2024 · 14 (6) · 309
DOI: 10.3390/bios14060309 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 17.06.2024. Verfasst von Deivasigamani Ranjith Kumar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Organic and Nanohybrid Electronics, Silesian University of Technology, Konarskiego 22B, 44-100 Gliwice, Poland. Hauptthemen laut MEDLINE: Sepsis, Biomarkers, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 132 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre.
Themen: Sepsis
Abstract (Originalsprache)
Sepsis is a life-threatening condition with high mortality rates due to delayed treatment of patients. The conventional methodology for blood diagnosis takes several hours, which suspends treatment, limits early drug administration, and affects the patient’s recovery. Thus, rapid, accurate, bedside (onsite), economical, and reliable sepsis biomarker reading of the clinical sample is an emergent need for patient lifesaving. Electrochemical label-free biosensors are specific and rapid devices that are able to perform analysis at the patient’s bedside; thus, they are considered an attractive methodology in a clinical setting. To reveal their full diagnostic potential, electrode architecture strategies of fabrication are highly desirable, particularly those able to preserve specific antibody–antigen attraction, restrict non-specific adsorption, and exhibit high sensitivity with a low detection limit for a target biomarker. The aim of this review is to provide state-of-the-art methodologies allowing the fabrication of ultrasensitive and highly selective electrochemical sensors for sepsis biomarkers. This review focuses on different methods of label-free biomarker sensors and discusses their advantages and disadvantages. Then, it highlights effective ways of avoiding false results and the role of molecular labels and functionalization. Recent literature on electrode materials and antibody grafting strategies is discussed, and the most efficient methodology for overcoming the non-specific attraction issues is listed. Finally, we discuss the existing electrode architecture for specific biomarker readers and promising tactics for achieving quick and low detection limits for sepsis biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Centre for Organic and Nanohybrid Electronics, Silesian University of Technology, Konarskiego 22B, 44-100 Gliwice, Poland.
- Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, M. Strzody 9, 44-100 Gliwice, Poland.
ORCID-Profile: Katarzyna Krukiewicz
Förderung
- National Science Centre
Zitieren
APA
Kumar, D. R., Banaś, A., & Krukiewicz, K. (2024). Challenges and Advances in Biomarker Detection for Rapid and Accurate Sepsis Diagnosis: An Electrochemical Approach. Biosensors, 14(6), 309. https://doi.org/10.3390/bios14060309
Vancouver
Kumar DR, Banaś A, Krukiewicz K. Challenges and Advances in Biomarker Detection for Rapid and Accurate Sepsis Diagnosis: An Electrochemical Approach. Biosensors. 2024;14(6):309. doi:10.3390/bios14060309
BibTeX
@article{Kumar2024,
author = {Kumar, Deivasigamani Ranjith and Banaś, Angelika and Krukiewicz, Katarzyna},
title = {Challenges and Advances in Biomarker Detection for Rapid and Accurate Sepsis Diagnosis: An Electrochemical Approach},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {6},
pages = {309},
doi = {10.3390/bios14060309}
}
EUVIMED