Fachartikel in der Zeitschrift Biosensors, online erschienen am 07.06.2024. Verfasst von Kundan Kumar Mishra und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA. Hauptthemen laut MEDLINE: Escherichia coli O157, Electrochemical Techniques, Biosensing Techniques, Water Microbiology. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
There is a pressing need to enhance early detection methods of E. coli O157:H7 to mitigate the occurrence and consequences of pathogenic contamination and associated outbreaks. This study highlights the efficacy of a portable electrochemical sensing platform that operates without faradaic processes towards detecting and quantifying E. coli O157:H7. It is specifically tailored for quick identification in potable water. The assay processing time is approximately 5 min, addressing the need for swift and efficient pathogen detection. The sensing platform was constructed utilizing specific, monoclonal E. coli antibodies, based on single-capture, non-faradaic, electrochemical immunoassay principles. The E. coli sensor assay underwent testing over a wide concentration range, spanning from 10 to 105 CFU/mL, and a limit of detection (LoD) of 1 CFU/mL was demonstrated. Significantly, the sensor’s performance remained consistent across studies, with both inter- and intra-study coefficients of variation consistently below 20%. To evaluate real-world feasibility, a comparative examination was performed between laboratory-based benchtop data and data obtained from the portable device. The proposed sensing platform exhibited remarkable sensitivity and selectivity, enabling the detection of minimal E. coli concentrations in potable water. This successful advancement positions it as a promising solution for prompt on-site detection, characterized by its portability and user-friendly operation. This study presents electrochemical-based sensors as significant contributors to ensuring food safety and public health. They play a crucial role in preventing the occurrence of epidemics and enhancing the supervision of water quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
- EnLiSense LLC, 1813 Audubon Pondway, Allen, TX 75013, USA.
ORCID-Profile: Vikram Narayanan Dhamu, Shalini Prasad
Zitieren
APA
Mishra, K. K., Dhamu, V. N., Jophy, C., Muthukumar, S., & Prasad, S. (2024). Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples. Biosensors, 14(6), 298. https://doi.org/10.3390/bios14060298
Vancouver
Mishra KK, Dhamu VN, Jophy C, Muthukumar S, Prasad S. Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples. Biosensors. 2024;14(6):298. doi:10.3390/bios14060298
BibTeX
@article{Mishra2024,
author = {Mishra, Kundan Kumar and Dhamu, Vikram Narayanan and Jophy, Chesna and Muthukumar, Sriram and Prasad, Shalini},
title = {Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {6},
pages = {298},
doi = {10.3390/bios14060298}
}
EUVIMED