EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel Ratiometric Photoelectrochemical Biosensor Based on Front and Back Illumination for Sensitive and Accurate Glutathione Sensing

Jie Huang, Florian Ion Tiberiu Petrescu iD, Bing Li, Likui Wang, Haiyan Zhu, Ying Li

Biosensors · 2024

DOI: 10.3390/bios14060285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Jie Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Key Laboratory of Synthetic and Biotechnology Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, …. Hauptthemen laut MEDLINE: Biosensing Techniques, Glutathione, Electrochemical Techniques, Titanium. Die Arbeit wurde bisher 5-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Support Program of Jiangsu Province, Fok Ying Tong Education Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ratiometric detection method has a strong attraction for photoelectrochemical bioanalysis due to its high reliability and real-time calibration. However, its implementation typically depends on the spatial resolution of equipment and the pairing of wavelength/potential with photoactive materials. In this paper, a novel ratiometric photoelectrochemical biosensor based on front and back illumination was prepared for the detection of glutathione (GSH). Unlike traditional ratio methods, this ratiometric biosensor does not require voltage and wavelength modulation, thereby avoiding potential crosstalk caused by voltage and wavelength modulation. Additionally, the formation of a heterojunction between mTiO2 and Ag2S is conducive to enhancing light absorption and promoting charge separation, thereby boosting the photocurrent signal. Apart from forming a heterojunction with TiO2, Ag2S also shows a specific affinity towards GSH, thus enhancing the selectivity of the mTiO2/Ag2S ratiometric photoelectrochemical biosensor. The results demonstrate that the ratiometric photoelectrochemical biosensor exhibits a good detection range and a low detection limit for GSH, while also possessing significant interference elimination capability. The GSH detection range is 0.01–10 mmol L−1 with a detection limit of 6.39 × 10−3 mmol·L−1. The relative standard deviation of 20 repeated detections is 0.664%. Impressively, the proposed novel ratiometric PEC biosensor demonstrates enviable universality, providing new insights for the design and construction of PEC ratiometric sensing platforms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGlutathioneElectrochemical TechniquesTitaniumLimit of Detection

Stichwörter der Autor:innen

glutathionephotoelectrochemical biosensorratiometric detection

Substanzen

GlutathioneTitaniumtitanium dioxide

Autor:innen und Institutionen

  • The Key Laboratory of Synthetic and Biotechnology Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi 214122, China.
  • Department of Mechanisms and Robots Theory, National University of Science and Technology Polytechnic Bucharest, 060042 Bucharest, Romania.

ORCID-Profile: Florian Ion Tiberiu Petrescu

Förderung

  • Science and Technology Support Program of Jiangsu Province
  • Fok Ying Tong Education Foundation

Zitieren

APA

Huang, J., Petrescu, F. I. T., Li, B., Wang, L., Zhu, H., & Li, Y. (2024). A Novel Ratiometric Photoelectrochemical Biosensor Based on Front and Back Illumination for Sensitive and Accurate Glutathione Sensing. Biosensors. https://doi.org/10.3390/bios14060285

Vancouver

Huang J, Petrescu FIT, Li B, Wang L, Zhu H, Li Y. A Novel Ratiometric Photoelectrochemical Biosensor Based on Front and Back Illumination for Sensitive and Accurate Glutathione Sensing. Biosensors. 2024. doi:10.3390/bios14060285

BibTeX
@article{Huang2024,
  author = {Huang, Jie and Petrescu, Florian Ion Tiberiu and Li, Bing and Wang, Likui and Zhu, Haiyan and Li, Ying},
  title = {A Novel Ratiometric Photoelectrochemical Biosensor Based on Front and Back Illumination for Sensitive and Accurate Glutathione Sensing},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14060285}
}