Rapid and Sensitive Detection of Inactivated SARS-CoV-2 Virus via Fiber-Optic and Electrochemical Impedance Spectroscopy Based Aptasensors
Biosensors · 07.05.2024 · 14 (5) · 231
DOI: 10.3390/bios14050231 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 07.05.2024. Verfasst von Can Xiao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Institute of Basic Medical Sciences, Beijing 100850, China. Hauptthemen laut MEDLINE: SARS-CoV-2, Aptamers, Nucleotide, Biosensing Techniques, Dielectric Spectroscopy. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing Municipal Natural Science Foundation.
Abstract (Originalsprache)
The development of rapid detection tools for viruses is vital for the prevention of pandemics and biothreats. Aptamers that target inactivated viruses are attractive for sensors due to their improved biosafety. Here, we evaluated a DNA aptamer (named as 6.9) that specifically binds to the inactivated SARS-CoV-2 virus with a low dissociation constant (KD = 9.6 nM) for the first time. Based on aptamer 6.9, we developed a fiber-optic evanescent wave (FOEW) biosensor. Inactivated SARS-CoV-2 and the Cy5.5-tagged short complementary strand competitively bound with the aptamer immobilized on the surface of the sensor. The detection of the inactivated SARS-CoV-2 virus was realized within six minutes with a limit of detection (LOD, S/N = 3) of 740 fg/mL. We also developed an electrochemical impedance aptasensor which exhibited an LOD of 5.1 fg/mL and high specificity. We further demonstrated that the LODs of the FOEW and electrochemical impedance aptasensors were, respectively, more than 1000 and 100,000 times lower than those of commercial colloidal gold test strips. We foresee that the facile aptamer isolation process and sensor design can be easily extended for the detection of other inactivated viruses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Beijing Institute of Basic Medical Sciences, Beijing 100850, China.
- Department of Chemistry, Capital Normal University, Xisanhuan North Road. 105, Beijing 100048, China.
ORCID-Profile: Xinhui Lou
Förderung
- Beijing Municipal Natural Science Foundation
Zitieren
APA
Xiao, C., Wang, N., Zhao, Y., Liu, X., Li, H., Huang, A., Wang, L., Lou, X., Gao, B., & Shao, N. (2024). Rapid and Sensitive Detection of Inactivated SARS-CoV-2 Virus via Fiber-Optic and Electrochemical Impedance Spectroscopy Based Aptasensors. Biosensors, 14(5), 231. https://doi.org/10.3390/bios14050231
Vancouver
Xiao C, Wang N, Zhao Y, Liu X, Li H, Huang A, et al. Rapid and Sensitive Detection of Inactivated SARS-CoV-2 Virus via Fiber-Optic and Electrochemical Impedance Spectroscopy Based Aptasensors. Biosensors. 2024;14(5):231. doi:10.3390/bios14050231
BibTeX
@article{Xiao2024,
author = {Xiao, Can and Wang, Nan and Zhao, Yuechao and Liu, Xuemei and Li, Hui and Huang, Aixue and Wang, Lin and Lou, Xinhui and Gao, Bo and Shao, Ningsheng},
title = {Rapid and Sensitive Detection of Inactivated SARS-CoV-2 Virus via Fiber-Optic and Electrochemical Impedance Spectroscopy Based Aptasensors},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {5},
pages = {231},
doi = {10.3390/bios14050231}
}
EUVIMED