EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method

Jingtao Wu, Jie Liu iD

Biosensors · 2024

DOI: 10.3390/bios14050221 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Biosensors, 2024. Verfasst von Jingtao Wu und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Science and Engineering, Southeast University, Nanjing 210096, China. Hauptthemen laut MEDLINE: Microwaves, Skin. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 128 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microwave radiometry (MWR) is instrumental in detecting thermal variations in skin tissue before anatomical changes occur, proving particularly beneficial in the early diagnosis of cancer and inflammation. This study concisely traces the evolution of microwave radiometers within the medical sector. By analyzing a plethora of pertinent studies and contrasting their strengths, weaknesses, and performance metrics, this research identifies the primary factors limiting temperature measurement accuracy. The review establishes the critical technologies necessary to overcome these limitations, examines the current state and prospective advancements of each technology, and proposes comprehensive implementation strategies. The discussion elucidates that the precise measurement of human surface and subcutaneous tissue temperatures using an MWR system is a complex challenge, necessitating an integration of antenna directionality for temperature measurement, radiometer error correction, hardware configuration, and the calibration and precision of a multilayer tissue forward and inversion method. This study delves into the pivotal technologies for non-invasive human tissue temperature monitoring in the microwave frequency range, offering an effective approach for the precise assessment of human epidermal and subcutaneous temperatures, and develops a non-contact microwave protocol for gauging subcutaneous tissue temperature distribution. It is anticipated that mass-produced measurement systems will deliver substantial economic and societal benefits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesSkinHumansSkin TemperatureRadiometryTemperature

Stichwörter der Autor:innen

early diagnosismicrowave radiometrynon-contactprecise measurementsubcutaneous tissue temperature

Autor:innen und Institutionen

  • School of Information Science and Engineering, Southeast University, Nanjing 210096, China.
  • The Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China.

ORCID-Profile: Jie Liu

Förderung

  • the National Natural Science Foundation of China
  • National Natural Science Foundation of China

Zitieren

APA

Wu, J., & Liu, J. (2024). Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method. Biosensors. https://doi.org/10.3390/bios14050221

Vancouver

Wu J, Liu J. Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method. Biosensors. 2024. doi:10.3390/bios14050221

BibTeX
@article{Wu2024,
  author = {Wu, Jingtao and Liu, Jie},
  title = {Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14050221}
}
Kostenlos starten →