EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors

Anastasiia Kudriavtseva iD, Stefan Jarić iD, Nikita Nekrasov iD, Alexey V Orlov iD, Ivana Gadjanski iD, Ivan Bobrinetskiy iD, Petr I Nikitin iD, Nikola Knežević iD

Biosensors · 2024

DOI: 10.3390/bios14050215 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Biosensors, 2024. Verfasst von Anastasiia Kudriavtseva und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Probe Microscopy and Nanotechnology, National Research University of Electronic Technology, Zelenograd, Moscow 124498, Russia. Hauptthemen laut MEDLINE: Graphite, Natriuretic Peptide, Brain, Biosensing Techniques, Transistors, Electronic. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Russian Science Foundation, Ministry of Science, Technological development and Innovation of the Republic of Serbia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers’ method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteNatriuretic Peptide, BrainBiosensing TechniquesTransistors, ElectronicPeptide FragmentsHumansLimit of DetectionGoldAptamers, NucleotideElectrodesBiomarkers

Stichwörter der Autor:innen

aptamerfield-effect transistorgraphenegraphene oxideheart failurepoint-of-care diagnostic

Substanzen

GraphiteNatriuretic Peptide, Brainpro-brain natriuretic peptide (1-76)graphene oxidePeptide FragmentsGoldAptamers, NucleotideBiomarkers

Autor:innen und Institutionen

  • Center for Probe Microscopy and Nanotechnology, National Research University of Electronic Technology, Zelenograd, Moscow 124498, Russia.
  • BioSense Institute-Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia.

ORCID-Profile: Anastasiia Kudriavtseva, Stefan Jarić, Nikita Nekrasov, Alexey V Orlov, Ivana Gadjanski, Ivan Bobrinetskiy, Petr I Nikitin, Nikola Knežević

Förderung

  • European Commission
  • Russian Science Foundation
  • Ministry of Science, Technological development and Innovation of the Republic of Serbia
  • Ministry of Science and Higher Education of the Russian Federation

Zitieren

APA

Kudriavtseva, A., Jarić, S., Nekrasov, N., Orlov, A. V., Gadjanski, I., Bobrinetskiy, I., Nikitin, P. I., & Knežević, N. (2024). Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors. Biosensors. https://doi.org/10.3390/bios14050215

Vancouver

Kudriavtseva A, Jarić S, Nekrasov N, Orlov AV, Gadjanski I, Bobrinetskiy I, et al. Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors. Biosensors. 2024. doi:10.3390/bios14050215

BibTeX
@article{Kudriavtseva2024,
  author = {Kudriavtseva, Anastasiia and Jarić, Stefan and Nekrasov, Nikita and Orlov, Alexey V and Gadjanski, Ivana and Bobrinetskiy, Ivan and Nikitin, Petr I and Knežević, Nikola},
  title = {Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14050215}
}
Kostenlos starten →