Weak Value Amplification-Based Biochip for Highly Sensitive Detection and Identification of Breast Cancer Exosomes
Biosensors · 2024
DOI: 10.3390/bios14040198 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Jingru Zhao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China. Hauptthemen laut MEDLINE: Exosomes, Breast Neoplasms, Biosensing Techniques, Gold. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Shenzhen Fundamental Research Program.
Abstract (Originalsprache)
Exosomes constitute an emerging biomarker for cancer diagnosis because they carry multiple proteins that reflect the origins of the parent cell. The highly sensitive detection of exosomes is a crucial prerequisite for the diagnosis of cancer. In this study, we report an exosome detection system based on quantum weak value amplification (WVA). The WVA detection system consists of a reflection detection light path and a Zr-ionized biochip. Zr-ionized biochips effectively capture exosomes through the specific interaction between zirconium dioxide and the phosphate groups on the lipid bilayer of exosomes. Aptamer-modified gold nanoparticles (Au NPs) are then used to specifically recognize proteins on exosomes to enhance the detection signal. The sensitivity and resolution of the detection system are 2944.07 nm/RIU and 1.22 × 10−5 RIU, respectively. The concentration of exosomes can be directly quantified by the WVA system, ranging from 105–107 particles/mL with the detection limit of 3 × 104 particles/mL. The use of Au NPs-EpCAM for the specific enhancement of breast cancer MDA-MB-231 exosomes is demonstrated. The results indicate that the WVA detection system can be a promising candidate for the detection of exosomes as tumor markers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
- School of Medicine, Tsinghua University, Beijing 100084, China.
ORCID-Profile: Shuqing Sun
Förderung
- National Natural Science Foundation of China
- Shenzhen Fundamental Research Program
Zitieren
APA
Zhao, J., Guan, X., Zhang, S., Sha, Z., & Sun, S. (2024). Weak Value Amplification-Based Biochip for Highly Sensitive Detection and Identification of Breast Cancer Exosomes. Biosensors. https://doi.org/10.3390/bios14040198
Vancouver
Zhao J, Guan X, Zhang S, Sha Z, Sun S. Weak Value Amplification-Based Biochip for Highly Sensitive Detection and Identification of Breast Cancer Exosomes. Biosensors. 2024. doi:10.3390/bios14040198
BibTeX
@article{Zhao2024,
author = {Zhao, Jingru and Guan, Xiaotian and Zhang, Sihao and Sha, Zhou and Sun, Shuqing},
title = {Weak Value Amplification-Based Biochip for Highly Sensitive Detection and Identification of Breast Cancer Exosomes},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14040198}
}
EUVIMED