Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors
Biosensors · 17.04.2024 · 14 (4) · 197
DOI: 10.3390/bios14040197 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 17.04.2024. Verfasst von Min Jung Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-d…. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanostructures, Spectrum Analysis, Raman, Viral Proteins. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 137 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Biomedical Research Institute of Jeonbuk National University Hospital, Bio & Medical Technology Development Program of the National Research Foundation (NRF).
Abstract (Originalsprache)
Controlling the progression of contagious diseases is crucial for public health management, emphasizing the importance of early viral infection diagnosis. In response, lateral flow assays (LFAs) have been successfully utilized in point-of-care (POC) testing, emerging as a viable alternative to more traditional diagnostic methods. Recent advancements in virus detection have primarily leveraged methods such as reverse transcription–polymerase chain reaction (RT-PCR), reverse transcription–loop-mediated isothermal amplification (RT-LAMP), and the enzyme-linked immunosorbent assay (ELISA). Despite their proven effectiveness, these conventional techniques are often expensive, require specialized expertise, and consume a significant amount of time. In contrast, LFAs utilize nanomaterial-based optical sensing technologies, including colorimetric, fluorescence, and surface-enhanced Raman scattering (SERS), offering quick, straightforward analyses with minimal training and infrastructure requirements for detecting viral proteins in biological samples. This review describes the composition and mechanism of and recent advancements in LFAs for viral protein detection, categorizing them into colorimetric, fluorescent, and SERS-based techniques. Despite significant progress, developing a simple, stable, highly sensitive, and selective LFA system remains a formidable challenge. Nevertheless, an advanced LFA system promises not only to enhance clinical diagnostics but also to extend its utility to environmental monitoring and beyond, demonstrating its potential to revolutionize both healthcare and environmental safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea.
- Department of Bioprocess Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea.
- Department of Biotechnology, Jeonbuk National University, 79 Gobongro, Iksan-si 54596, Jeollabuk-do, Republic of Korea.
ORCID-Profile: Jin-Ha Choi
Förderung
- National Research Foundation of Korea
- Biomedical Research Institute of Jeonbuk National University Hospital
- Bio & Medical Technology Development Program of the National Research Foundation (NRF)
Zitieren
APA
Kim, M. J., Haizan, I., Ahn, M. J., Park, D. H., & Choi, J. H. (2024). Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors. Biosensors, 14(4), 197. https://doi.org/10.3390/bios14040197
Vancouver
Kim MJ, Haizan I, Ahn MJ, Park DH, Choi JH. Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors. Biosensors. 2024;14(4):197. doi:10.3390/bios14040197
BibTeX
@article{Kim2024,
author = {Kim, Min Jung and Haizan, Izzati and Ahn, Min Ju and Park, Dong-Hyeok and Choi, Jin-Ha},
title = {Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {4},
pages = {197},
doi = {10.3390/bios14040197}
}
EUVIMED