A Careful Insight into DDI-Type Receptor Layers on the Way to Improvement of Click-Biology-Based Immunosensors
Biosensors · 2024
DOI: 10.3390/bios14030136 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Sylwia Karoń und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Diagnostics, Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsa…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development in Poland under the Smart Growth Operational Programme co-financed by the European Regional Development Fund, Ministry of Education and Science in Poland, European Regional Development Fund.
Abstract (Originalsprache)
Protein-based microarrays are important tools for high-throughput medical diagnostics, offering versatile platforms for multiplex immunodetection. However, challenges arise in protein microarrays due to the heterogeneous nature of proteins and, thus, differences in their immobilization conditions. This article advocates DNA-directed immobilization (DDI) as a solution, emphasizing its rapid and cost-effective fabrication of biosensing platforms. Thiolated single-stranded DNA and its analogues, such as ZNA® and PNA probes, were used to immobilize model proteins (anti-CRP antibodies and SARS-CoV nucleoprotein). The study explores factors influencing DDI-based immunosensor performance, including the purity of protein-DNA conjugates and the stability of their duplexes with DNA and analogues. It also provides insight into backfilling agent type and probe surface density. The research reveals that single-component monolayers lack protection against protein adsorption, while mixing the probes with long-chain ligands may hinder DNA-protein conjugate anchoring. Conventional DNA probes offer slightly higher surface density, while ZNA® probes exhibit better binding efficiency. Despite no enhanced stability in different ionic strength media, the cost-effectiveness of DNA probes led to their preference. The findings contribute to advancing microarray technology, paving the way for new generations of DDI-based multiplex platforms for rapid and robust diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Diagnostics, Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland.
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland.
ORCID-Profile: Marcin Drozd, Elżbieta Malinowska
Förderung
- National Centre for Research and Development in Poland under the Smart Growth Operational Programme co-financed by the European Regional Development Fund
- Ministry of Education and Science in Poland
- European Regional Development Fund
- Warsaw University of Technology
- Ministry of Education and Science, Poland
Zitieren
APA
Karoń, S., Drozd, M., & Malinowska, E. (2024). A Careful Insight into DDI-Type Receptor Layers on the Way to Improvement of Click-Biology-Based Immunosensors. Biosensors. https://doi.org/10.3390/bios14030136
Vancouver
Karoń S, Drozd M, Malinowska E. A Careful Insight into DDI-Type Receptor Layers on the Way to Improvement of Click-Biology-Based Immunosensors. Biosensors. 2024. doi:10.3390/bios14030136
BibTeX
@article{Karo2024,
author = {Karoń, Sylwia and Drozd, Marcin and Malinowska, Elżbieta},
title = {A Careful Insight into DDI-Type Receptor Layers on the Way to Improvement of Click-Biology-Based Immunosensors},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14030136}
}
EUVIMED