EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People

Ke-Jing Li, Nicky Lok-Yi Wong, Man-Ching Law, Freddy Man-Hin Lam iD, Hoi-Ching Wong, Tsz-On Chan, Kit-Naam Wong, Yong-Ping Zheng iD, Qi-Yao Huang, Arnold Yu-Lok Wong iD, Timothy Chi-Yui Kwok iD, Christina Zong-Hao Ma iD

Biosensors · 25.11.2023 · 13 (12) · 998

DOI: 10.3390/bios13120998 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 25.11.2023. Verfasst von Ke-Jing Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China. Hauptthemen laut MEDLINE: Accidental Falls, Postural Balance. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hong Kong Research Grants Council (RGC) Direct Allocation Grant - Funding Support to Small Projects, Research Institute for Smart Ageing, The Hong Kong Polytechnic University, The Hong Kong Polytechnic University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in community-dwelling older people remain unclear. Therefore, this study evaluated the performance of a commercially available IMU sensor-based fall risk assessment system among 20 community-dwelling older recurrent fallers (with a history of ≥2 falls in the past 12 months) and 20 community-dwelling older non-fallers (no history of falls in the past 12 months), together with applying the clinical scale of the Mini-Balance Evaluation Systems Test (Mini-BESTest). The results show that the IMU sensor-based system exhibited a significant moderate to excellent test–retest reliability (ICC = 0.838, p < 0.001), an acceptable level of internal consistency reliability (Spearman’s rho = 0.471, p = 0.002), an acceptable convergent validity (Cronbach’s α = 0.712), and an area under the curve (AUC) value of 0.590 for the IMU sensor-based receiver-operating characteristic (ROC) curve. The findings suggest that while the evaluated IMU sensor-based system exhibited good reliability and acceptable validity, it might not be able to fully identify the recurrent fallers and non-fallers in a community-dwelling older population. Further system optimization is still needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Accidental FallsPostural BalanceHumansAgedReproducibility of ResultsRisk AssessmentROC Curve

Stichwörter der Autor:innen

community-dwelling older peoplefall risk assessmentinertial measurement unit (IMU) sensorthe Mini-Balance Evaluation Systems Test (Mini-BESTest)wearable system

Autor:innen und Institutionen

  • Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Department of Medicine & Therapeutics, The Chinese University of Hong Kong, Hong Kong SAR, China.

ORCID-Profile: Freddy Man-Hin Lam, Yong-Ping Zheng, Arnold Yu-Lok Wong, Timothy Chi-Yui Kwok, Christina Zong-Hao Ma

Förderung

  • Hong Kong Research Grants Council (RGC) Direct Allocation Grant - Funding Support to Small Projects
  • Research Institute for Smart Ageing, The Hong Kong Polytechnic University
  • The Hong Kong Polytechnic University
  • Associated Money, The Hong Kong Polytechnic University
  • Hong Kong Research Grants Council
  • Hong Kong Polytechnic University

Zitieren

APA

Li, K. J., Wong, N. L., Law, M. C., Lam, F. M., Wong, H. C., Chan, T. O., Wong, K. N., Zheng, Y. P., Huang, Q. Y., Wong, A. Y., Kwok, T. C., & Ma, C. Z. (2023). Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People. Biosensors, 13(12), 998. https://doi.org/10.3390/bios13120998

Vancouver

Li KJ, Wong NL, Law MC, Lam FM, Wong HC, Chan TO, et al. Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People. Biosensors. 2023;13(12):998. doi:10.3390/bios13120998

BibTeX
@article{Li2023,
  author = {Li, Ke-Jing and Wong, Nicky Lok-Yi and Law, Man-Ching and Lam, Freddy Man-Hin and Wong, Hoi-Ching and Chan, Tsz-On and Wong, Kit-Naam and Zheng, Yong-Ping and Huang, Qi-Yao and Wong, Arnold Yu-Lok and Kwok, Timothy Chi-Yui and Ma, Christina Zong-Hao},
  title = {Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People},
  journal = {Biosensors},
  year = {2023},
  volume = {13},
  number = {12},
  pages = {998},
  doi = {10.3390/bios13120998}
}
Kostenlos starten →