Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests
Biosensors · 15.09.2023 · 13 (9) · 885
DOI: 10.3390/bios13090885 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 15.09.2023. Verfasst von Jocelyn Reynolds und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA. Hauptthemen laut MEDLINE: Microfluidics, Nucleic Acids. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 149 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, University of Arizona.
Abstract (Originalsprache)
Isothermal nucleic acid amplification tests have recently gained popularity over polymerase chain reaction (PCR), as they only require a constant temperature and significantly simplify nucleic acid amplification. Recently, numerous attempts have been made to incorporate paper microfluidics into these isothermal amplification tests. Paper microfluidics (including lateral flow strips) have been used to extract nucleic acids, amplify the target gene, and detect amplified products, all toward automating the process. We investigated the literature from 2020 to the present, i.e., since the onset of the COVID-19 pandemic, during which a significant surge in isothermal amplification tests has been observed. Paper microfluidic detection has been used extensively for recombinase polymerase amplification (RPA) and its related methods, along with loop-mediated isothermal amplification (LAMP) and rolling circle amplification (RCA). Detection was conducted primarily with colorimetric and fluorometric methods, although a few publications demonstrated flow distance- and surface-enhanced Raman spectroscopic (SERS)-based detection. A good number of publications could be found that demonstrated both amplification and detection on paper microfluidic platforms. A small number of publications could be found that showed extraction or all three procedures (i.e., fully integrated systems) on paper microfluidic platforms, necessitating the need for future work.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA.
- Department of Neuroscience, The University of Arizona, Tucson, AZ 85721, USA.
ORCID-Profile: Jeong-Yeol Yoon
Förderung
- NIEHS NIH HHS
- University of Arizona
Zitieren
APA
Reynolds, J., Loeffler, R. S., Leigh, P. J., Lopez, H. A., & Yoon, J. Y. (2023). Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests. Biosensors, 13(9), 885. https://doi.org/10.3390/bios13090885
Vancouver
Reynolds J, Loeffler RS, Leigh PJ, Lopez HA, Yoon JY. Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests. Biosensors. 2023;13(9):885. doi:10.3390/bios13090885
BibTeX
@article{Reynolds2023,
author = {Reynolds, Jocelyn and Loeffler, Reid S and Leigh, Preston J and Lopez, Hannah A and Yoon, Jeong-Yeol},
title = {Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests},
journal = {Biosensors},
year = {2023},
volume = {13},
number = {9},
pages = {885},
doi = {10.3390/bios13090885}
}
EUVIMED