Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Jaskirat Singh Batra und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77840, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Wearable Electronic Devices, Lentivirus, Molecularly Imprinted Polymers. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bill and Melinda Gates Foundation, Department of Integrative Biology and Pharmacology of the University of Texas Health Science Center at Houston.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The coronavirus disease (COVID-19) pandemic has increased pressure to develop low-cost, compact, user-friendly, and ubiquitous virus sensors for monitoring infection outbreaks in communities and preventing economic damage resulting from city lockdowns. As proof of concept, we developed a wearable paper-based virus sensor based on a molecular imprinting technique, using a conductive polyaniline (PANI) polymer to detect the lentivirus as a test sample. This sensor detected the lentivirus with a 4181 TU/mL detection limit in liquid and 0.33% to 2.90% detection efficiency in aerosols at distances ranging from 30 cm to 60 cm. For fabrication, a mixture of a PANI monomer solution and virus were polymerized together to form a conductive PANI sensing element on a polyethylene terephthalate (PET) paper substrate. The sensing element exhibited formation of virus recognition sites after the removal of the virus via ultrasound sonication. A dry measurement technique was established that showed aerosol virus detection by the molecularly imprinted sensors within 1.5 h of virus spraying. This was based on the mechanism via which dispensing virus droplets on the PANI sensing element induced hybridization of the virus and molecularly imprinted virus recognition templates in PANI, influencing the conductivity of the PANI film upon drying. Interestingly, the paper-based virus sensor was easily integrated with a wearable face mask for the detection of viruses in aerosols. Since the paper sensor with molecular imprinting of virus recognition sites showed excellent stability in dry conditions for long periods of time, unlike biological reagents, this wearable biosensor will offer an alternative approach to monitoring virus infections in communities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesWearable Electronic DevicesLentivirusMolecularly Imprinted PolymersHumansAerosolsMolecular ImprintingAniline CompoundsCOVID-19SARS-CoV-2PolymersLimit of DetectionElectric Conductivity

Stichwörter der Autor:innen

conductive polymerlentivirusmolecular imprintingvirus sensorwearable paper sensor

Substanzen

polyanilineAerosolsAniline CompoundsMolecularly Imprinted PolymersPolymers

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77840, USA.
  • Department of Integrative Biology and Pharmacology, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA.
  • The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston TX 77030, USA.
  • Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Graduate School of Information, Production and System Research, Waseda University, Fukuoka 808-0135, Japan.

ORCID-Profile: Ting-Yen Chi, Mo-Fan Huang, Dung-Fang Lee, Jun Kameoka

Förderung

  • Bill and Melinda Gates Foundation
  • Department of Integrative Biology and Pharmacology of the University of Texas Health Science Center at Houston

Zitieren

APA

Batra, J. S., Chi, T. Y., Huang, M. F., Zhu, D., Chen, Z., Lee, D. F., & Kameoka, J. (2023). Wearable Biosensor with Molecularly Imprinted Conductive Polymer Structure to Detect Lentivirus in Aerosol. Biosensors. https://doi.org/10.3390/bios13090861

Vancouver

Batra JS, Chi TY, Huang MF, Zhu D, Chen Z, Lee DF, et al. Wearable Biosensor with Molecularly Imprinted Conductive Polymer Structure to Detect Lentivirus in Aerosol. Biosensors. 2023. doi:10.3390/bios13090861

BibTeX
@article{Batra2023,
  author = {Batra, Jaskirat Singh and Chi, Ting-Yen and Huang, Mo-Fan and Zhu, Dandan and Chen, Zheyuan and Lee, Dung-Fang and Kameoka, Jun},
  title = {Wearable Biosensor with Molecularly Imprinted Conductive Polymer Structure to Detect Lentivirus in Aerosol},
  journal = {Biosensors},
  year = {2023},
  doi = {10.3390/bios13090861}
}
Kostenlos starten →