A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor
Biosensors · 2023
DOI: 10.3390/bios13090841 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Vinayak J Bhat und 4 weiteren Autor:innen. Beteiligte Einrichtung: Leibniz Institute of Photonic Technology, Albert-Einstein-Str. 9, 07745 Jena, Germany. Hauptthemen laut MEDLINE: Silicon, Phosphates. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Thüringer Aufbaubank.
Abstract (Originalsprache)
We present a novel and easy approach using a silicon-based impedance chip to determine the concentration of the given aqueous buffer solution. An accurate determination of the post-dilution concentration of the buffers is necessary for ensuring optimal buffer capacity, pH stability, and to assess solution reproducibility. In this study, we focused on phosphate buffer as the test liquid to achieve precise post-dilution concentration determinations. The impedance chip consisting of a top gold ring electrode, where a test volume of 20 μL to 30 μL of phosphate buffer was introduced for impedance measurements within the frequency range of 40 Hz to 1 MHz. For impedance investigation, we used phosphate buffers with three different pH values, and the impedance was measured after diluting the phosphate buffers to a concentration of 1.00 M, 0.75 M, 0.50 M, 0.25 M, 0.10 M, 0.05 M, and 0.01 M. In order to analyze the distinctive changes in the measured impedance, an equivalent circuit was proposed and modeled. From the impedance modeling, we report that the circuit parameter RAu/Si showed exponential dependence on the concentration of phosphate buffer and no dependence on the pH values of the phosphate buffer and on the added volume inside the ring electrode. The proposed silicon-based impedance chip is quick and uses reduced liquid volume for post-dilution concentration measurements of buffers and has perspective applications in the pharmaceutical and biological domains for regulating, monitoring, and quality control of the buffers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Leibniz Institute of Photonic Technology, Albert-Einstein-Str. 9, 07745 Jena, Germany.
- Institute of Solid State Physics, Friedrich Schiller University Jena, Helmholtzweg 3, 07743 Jena, Germany.
- Institute of Physical Chemistry, Friedrich Schiller University Jena, Helmholtzweg 4, 07743 Jena, Germany.
- InfectoGnostics Research Campus, 07743 Jena, Germany.
ORCID-Profile: Daniel Blaschke, Ralf Ehricht
Förderung
- Thüringer Aufbaubank
Zitieren
APA
Bhat, V. J., Blaschke, D., Müller, E., Ehricht, R., & Schmidt, H. (2023). A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor. Biosensors. https://doi.org/10.3390/bios13090841
Vancouver
Bhat VJ, Blaschke D, Müller E, Ehricht R, Schmidt H. A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor. Biosensors. 2023. doi:10.3390/bios13090841
BibTeX
@article{Bhat2023,
author = {Bhat, Vinayak J and Blaschke, Daniel and Müller, Elke and Ehricht, Ralf and Schmidt, Heidemarie},
title = {A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13090841}
}
EUVIMED