A Label-Free and Antibody-Free Molecularly Imprinted Polymer-Based Impedimetric Sensor for NSCLC-Cells-Derived Exosomes Detection
Biosensors · 13.06.2023 · 13 (6) · 647
DOI: 10.3390/bios13060647 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 13.06.2023. Verfasst von Jingbo Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Science, Xiamen University, 4221 Xiang'an South Road, Xiamen 361102, China. Hauptthemen laut MEDLINE: Carcinoma, Non-Small-Cell Lung, Molecular Imprinting, Exosomes, Lung Neoplasms. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Education Department of Fujian Province, Xiamen Municipal Bureau of Science and Technology.
Abstract (Originalsprache)
In this study, a label-free and antibody-free impedimetric biosensor based on molecularly imprinting technology for exosomes derived from non-small-cell lung cancer (NSCLC) cells was established. Involved preparation parameters were systematically investigated. In this design, with template exosomes anchored on a glassy carbon electrode (GCE) by decorated cholesterol molecules, the subsequent electro-polymerization of APBA and elution procedure afforded a selective adsorption membrane for template A549 exosomes. The adsorption of exosomes caused a rise in the impedance of the sensor, so the concentration of template exosomes can be quantified by monitoring the impedance of GCEs. Each procedure in the establishment of the sensor was monitored with a corresponding method. Methodological verification showed great sensitivity and selectivity of this method with an LOD = 2.03 × 103 and an LOQ = 4.10 × 104 particles/mL. By introducing normal cells and other cancer cells derived exosomes as interference, high selectivity was proved. Accuracy and precision were measured, with an obtained average recovery ratio of 100.76% and a resulting RSD of 1.86%. Additionally, the sensors’ performance was retained at 4 °C for a week or after undergoing elution and re-adsorption cycles seven times. In summary, the sensor is competitive for clinical translational application and improving the prognosis and survival for NSCLC patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Pharmaceutical Science, Xiamen University, 4221 Xiang'an South Road, Xiamen 361102, China.
- Department of Cardiac Surgery, Xiamen Cardiovascular Hospital, Xiamen University, 2999 Jinshan Road, Xiamen 361010, China.
ORCID-Profile: Jingbo Zhang, Qing Chen
Förderung
- Education Department of Fujian Province
- Xiamen Municipal Bureau of Science and Technology
Zitieren
APA
Zhang, J., Chen, Q., Gao, X., Lin, Q., Suo, Z., Wu, D., Wu, X., & Chen, Q. (2023). A Label-Free and Antibody-Free Molecularly Imprinted Polymer-Based Impedimetric Sensor for NSCLC-Cells-Derived Exosomes Detection. Biosensors, 13(6), 647. https://doi.org/10.3390/bios13060647
Vancouver
Zhang J, Chen Q, Gao X, Lin Q, Suo Z, Wu D, et al. A Label-Free and Antibody-Free Molecularly Imprinted Polymer-Based Impedimetric Sensor for NSCLC-Cells-Derived Exosomes Detection. Biosensors. 2023;13(6):647. doi:10.3390/bios13060647
BibTeX
@article{Zhang2023,
author = {Zhang, Jingbo and Chen, Quancheng and Gao, Xuemin and Lin, Qian and Suo, Ziqin and Wu, Di and Wu, Xijie and Chen, Qing},
title = {A Label-Free and Antibody-Free Molecularly Imprinted Polymer-Based Impedimetric Sensor for NSCLC-Cells-Derived Exosomes Detection},
journal = {Biosensors},
year = {2023},
volume = {13},
number = {6},
pages = {647},
doi = {10.3390/bios13060647}
}
EUVIMED