EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biomolecular Monitoring Tool Based on Lab-on-Chip for Virus Detection

Francesca Costantini iD, Nicola Lovecchio iD, Manasa Nandimandalam, Ariana Manglli, Francesco Faggioli iD, Mara Biasin iD, Cesare Manetti, Pio Federico Roversi iD, Augusto Nascetti iD, Giampiero de Cesare iD, Domenico Caputo iD

Biosensors · 12.05.2023 · 13 (5) · 544

DOI: 10.3390/bios13050544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 12.05.2023. Verfasst von Francesca Costantini und 10 weiteren Autor:innen. Beteiligte Einrichtung: CREA Research Centre for Plant Protection and Certification, 00156 Rome, Italy. Hauptthemen laut MEDLINE: Lab-On-A-Chip Devices, Viruses. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Foreign Affairs and International Cooperation (MAECI), Ministry of University and Research (MUR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lab-on-Chip (LoC) devices for performing real-time PCR are advantageous compared to standard equipment since these systems allow to conduct in-field quick analysis. The development of LoCs, where the components for performing the nucleic acid amplification are all integrated, can be an issue. In this work, we present a LoC-PCR device where thermalization, temperature control and detection elements are all integrated on a single glass substrate named System-on-Glass (SoG) obtained using metal thin-film deposition. By using a microwell plate optically coupled with the SoG, real-time reverse transcriptase PCR of RNA extracted from both a plant and human virus has been carried out in the developed LoC-PCR device. The limit of detection and time of analysis for the detection of the two viruses by using the LoC-PCR were compared with those achieved by standard equipment. The results showed that the two systems can detect the same concentration of RNA; however, the LoC-PCR performs the analysis in half of the time compared to the standard thermocycler, with the advantage of the portability, leading to a point-of-care device for several diagnostic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lab-On-A-Chip DevicesVirusesHumansNucleic Acid Amplification TechniquesReal-Time Polymerase Chain ReactionRNA, Viral

Stichwörter der Autor:innen

Lab-on-ChipSystem-on-Glassreal-time RT-PCRvirus detection

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • CREA Research Centre for Plant Protection and Certification, 00156 Rome, Italy.
  • Department of Environmental Biology, Sapienza University of Rome, 00185 Rome, Italy.
  • Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy.
  • Department of Biomedical and Clinical Sciences, University of Milan, Via G.B. Grassi, 20122 Milan, Italy.
  • School of Aerospace Engineering, Sapienza University of Rome, 00138 Rome, Italy.

ORCID-Profile: Francesca Costantini, Nicola Lovecchio, Francesco Faggioli, Mara Biasin, Pio Federico Roversi, Augusto Nascetti, Giampiero de Cesare, Domenico Caputo

Förderung

  • Italian Ministry of Foreign Affairs and International Cooperation (MAECI)
  • Ministry of University and Research (MUR)

Zitieren

APA

Costantini, F., Lovecchio, N., Nandimandalam, M., Manglli, A., Faggioli, F., Biasin, M., Manetti, C., Roversi, P. F., Nascetti, A., de Cesare, G., & Caputo, D. (2023). Biomolecular Monitoring Tool Based on Lab-on-Chip for Virus Detection. Biosensors, 13(5), 544. https://doi.org/10.3390/bios13050544

Vancouver

Costantini F, Lovecchio N, Nandimandalam M, Manglli A, Faggioli F, Biasin M, et al. Biomolecular Monitoring Tool Based on Lab-on-Chip for Virus Detection. Biosensors. 2023;13(5):544. doi:10.3390/bios13050544

BibTeX
@article{Costantini2023,
  author = {Costantini, Francesca and Lovecchio, Nicola and Nandimandalam, Manasa and Manglli, Ariana and Faggioli, Francesco and Biasin, Mara and Manetti, Cesare and Roversi, Pio Federico and Nascetti, Augusto and de Cesare, Giampiero and Caputo, Domenico},
  title = {Biomolecular Monitoring Tool Based on Lab-on-Chip for Virus Detection},
  journal = {Biosensors},
  year = {2023},
  volume = {13},
  number = {5},
  pages = {544},
  doi = {10.3390/bios13050544}
}
Kostenlos starten →