EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of an Enzymatic Biosensor Using Glutamate Oxidase on Organic–Inorganic-Structured, Electrospun Nanofiber-Modified Electrodes for Monosodium Glutamate Detection

Hamdiye Atilgan iD, Betul Unal iD, Esra Evrim Yalcinkaya iD, Gizem Evren iD, Gozde Atik iD, Fatma Ozturk Kirbay iD, Nur Melis Kilic iD, Dilek Odaci iD

Biosensors · 28.03.2023 · 13 (4) · 430

DOI: 10.3390/bios13040430 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 28.03.2023. Verfasst von Hamdiye Atilgan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey. Hauptthemen laut MEDLINE: Nanofibers, Dendrimers, Biosensing Techniques, Chitosan. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Turkey, University Students at the Undergraduate Level.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Herein, dendrimer-modified montmorillonite (Mt)-decorated poly-Ɛ-caprolactone (PCL) and chitosan (CHIT)-based nanofibers were prepared. Mt was modified with a poly(amidoamine) generation 1 (PAMAMG1) dendrimer, and the obtained PAMAMG1–Mt was incorporated into the PCL–CHIT nanofiber’s structure. The PCL–CHIT/PAMAMG1–Mt nanofibers were conjugated with glutamate oxidase (GluOx) to design a bio-based detection system for monosodium glutamate (MSG). PAMAMG1–Mt was added to the PCL–CHIT backbone to provide a multipoint binding side to immobilize GluOx via covalent bonds. After the characterization of PCL–CHIT/PAMAMG1–Mt/GluOx, it was calibrated for MSG. The linear ranges were determined from 0.025 to 0.25 mM MSG using PCL–CHIT/Mt/GluOx and from 0.0025 to 0.175 mM MSG using PCL–CHIT/PAMAMG1–Mt/GluOx (with a detection limit of 7.019 µM for PCL–CHIT/Mt/GluOx and 1.045 µM for PCL–CHIT/PAMAMG1–Mt/GluOx). Finally, PCL–CHIT/PAMAMG1–Mt/GluOx was applied to analyze MSG content in tomato soup without interfering with the sample matrix, giving a recovery percentage of 103.125%. Hence, the nanofiber modification with dendrimer-intercalated Mt and GluOx conjugation onto the formed nanocomposite structures was performed, and the PCL–CHIT/PAMAMG1–Mt/GluOx system was successfully developed for MSG detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NanofibersDendrimersBiosensing TechniquesChitosanSodium GlutamateElectrodes

Stichwörter der Autor:innen

MSGelectrochemical methodmontmorillonitenanobiotechnologynanofibernanomaterial

Substanzen

Sodium GlutamateDendrimersChitosan

Autor:innen und Institutionen

  • Department of Biochemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey.
  • Department of Chemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey.

ORCID-Profile: Hamdiye Atilgan, Betul Unal, Esra Evrim Yalcinkaya, Gizem Evren, Gozde Atik, Fatma Ozturk Kirbay, Nur Melis Kilic, Dilek Odaci

Förderung

  • Scientific and Technological Research Council of Turkey
  • University Students at the Undergraduate Level

Zitieren

APA

Atilgan, H., Unal, B., Yalcinkaya, E. E., Evren, G., Atik, G., Ozturk Kirbay, F., Kilic, N. M., & Odaci, D. (2023). Development of an Enzymatic Biosensor Using Glutamate Oxidase on Organic–Inorganic-Structured, Electrospun Nanofiber-Modified Electrodes for Monosodium Glutamate Detection. Biosensors, 13(4), 430. https://doi.org/10.3390/bios13040430

Vancouver

Atilgan H, Unal B, Yalcinkaya EE, Evren G, Atik G, Ozturk Kirbay F, et al. Development of an Enzymatic Biosensor Using Glutamate Oxidase on Organic–Inorganic-Structured, Electrospun Nanofiber-Modified Electrodes for Monosodium Glutamate Detection. Biosensors. 2023;13(4):430. doi:10.3390/bios13040430

BibTeX
@article{Atilgan2023,
  author = {Atilgan, Hamdiye and Unal, Betul and Yalcinkaya, Esra Evrim and Evren, Gizem and Atik, Gozde and Ozturk Kirbay, Fatma and Kilic, Nur Melis and Odaci, Dilek},
  title = {Development of an Enzymatic Biosensor Using Glutamate Oxidase on Organic–Inorganic-Structured, Electrospun Nanofiber-Modified Electrodes for Monosodium Glutamate Detection},
  journal = {Biosensors},
  year = {2023},
  volume = {13},
  number = {4},
  pages = {430},
  doi = {10.3390/bios13040430}
}
Kostenlos starten →