EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New, Extremely Sensitive, Turn-Off Optical Sensor Utilizing Schiff Base for Fast Detection of Cu(II)

Lotfi M Aroua iD, Reham Ali iD, Abuzar E A E Albadri, Sabri Messaoudi iD, Fahad M Alminderej, Sayed M Saleh iD

Biosensors · 2023

DOI: 10.3390/bios13030359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Lotfi M Aroua und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia. Hauptthemen laut MEDLINE: Schiff Bases, Fluorescent Dyes. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Throughout this research, a unique optical sensor for detecting one of the most dangerous heavy metal ions, Cu(II), was designed and developed. The (4-mercaptophenyl) iminomethylphenyl naphthalenyl carbamate (MNC) sensor probe was effectively prepared. The Schiff base of the sensor shows a “turn-off” state with excellent sensitivity to Cu(II) ions. This innovative fluorescent chemosensor possesses distinctive optical features with a substantial Stocks shift (about 114 nm). In addition, MNC has remarkable selectivity for Cu(II) relative to other cations. Density functional theory (DFT) and the time-dependent DFT (TDDFT) theoretical calculations were performed to examine Cu(II) chelation structures and associated electronic properties in solution, and the results indicate that the luminescence quenching in this complex is due to ICT. Chelation-quenched fluorescence is responsible for the internal charge transfer (ICT)-based selectivity of the MNC sensing molecule for Cu(II) ions. In a 1:9 (v/v) DMSO-HEPES buffer (20 mM, pH = 7.4) solution, Fluorescence and UV-Vis absorption of the MNC probe and Cu(II) ions were investigated. By utilizing a solution containing several metal ions, the interference of other metal ions was studied. This MNC molecule has outstanding selectivity and sensitivity, as well as a low LOD (1.45 nM). Consequently, these distinctive properties enable it to find the copper metal ions across an actual narrow dynamic range (0–1.2 M Cu(II)). The reversibility of the sensor was obtained by employing an EDTA as a powerful chelating agent.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Schiff BasesFluorescent DyesSpectrometry, FluorescenceCopperMetalsIons

Stichwörter der Autor:innen

chemical analysiscopperfluorescenceoptical propertiessensorsynthesis

Substanzen

Schiff BasesFluorescent DyesCopperMetalsIons

Autor:innen und Institutionen

  • Department of Chemistry, College of Science, Qassim University, Buraidah 51452, Saudi Arabia.
  • Laboratory of Structural Organic Chemistry-Synthesis and Physicochemical Studies (LR99ES14), Department of Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, Tunis 2092, Tunisia.
  • Faculty of Sciences of Bizerte, Carthage University, Jarzouna, Bizerte 7021, Tunisia.
  • Chemistry Department, Faculty of Science, Suez University, Suez 43518, Egypt.
  • Chemistry Branch, Department of Science and Mathematics, Faculty of Petroleum and Mining Engineering, Suez University, Suez 43721, Egypt.

ORCID-Profile: Lotfi M Aroua, Reham Ali, Sabri Messaoudi, Sayed M Saleh

Zitieren

APA

Aroua, L. M., Ali, R., Albadri, A. E. A. E., Messaoudi, S., Alminderej, F. M., & Saleh, S. M. (2023). A New, Extremely Sensitive, Turn-Off Optical Sensor Utilizing Schiff Base for Fast Detection of Cu(II). Biosensors. https://doi.org/10.3390/bios13030359

Vancouver

Aroua LM, Ali R, Albadri AEAE, Messaoudi S, Alminderej FM, Saleh SM. A New, Extremely Sensitive, Turn-Off Optical Sensor Utilizing Schiff Base for Fast Detection of Cu(II). Biosensors. 2023. doi:10.3390/bios13030359

BibTeX
@article{Aroua2023,
  author = {Aroua, Lotfi M and Ali, Reham and Albadri, Abuzar E A E and Messaoudi, Sabri and Alminderej, Fahad M and Saleh, Sayed M},
  title = {A New, Extremely Sensitive, Turn-Off Optical Sensor Utilizing Schiff Base for Fast Detection of Cu(II)},
  journal = {Biosensors},
  year = {2023},
  doi = {10.3390/bios13030359}
}
Kostenlos starten →