Multi-Parameter Detection of Urine Based on Electropolymerized PANI: PSS/AuNPs/SPCE
Biosensors · 14.02.2023 · 13 (2) · 272
DOI: 10.3390/bios13020272 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 14.02.2023. Verfasst von Dong Wang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instr…. Hauptthemen laut MEDLINE: Metal Nanoparticles, Renal Insufficiency, Chronic, Biosensing Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province, China, Key Research and Development Program of Zhejiang Province, China.
Abstract (Originalsprache)
Urine analysis is widely used in clinical practice to indicate human heathy status and is important for diagnosing chronic kidney disease (CKD). Ammonium ions (NH4+), urea, and creatinine metabolites are main clinical indicators in urine analysis of CKD patients. In this paper, NH4+ selective electrodes were prepared using electropolymerized polyaniline-polystyrene sulfonate (PANI: PSS), and urea- and creatinine-sensing electrodes were prepared by modifying urease and creatinine deiminase, respectively. First, PANI: PSS was modified on the surface of an AuNPs-modified screen-printed electrode, as a NH4+-sensitive film. The experimental results showed that the detection range of the NH4+ selective electrode was 0.5~40 mM, and the sensitivity reached 192.6 mA M−1 cm−2 with good selectivity, consistency, and stability. Based on the NH4+-sensitive film, urease and creatinine deaminase were modified by enzyme immobilization technology to achieve urea and creatinine detection, respectively. Finally, we further integrated NH4+, urea, and creatinine electrodes into a paper-based device and tested real human urine samples. In summary, this multi-parameter urine testing device offers the potential for point-of-care testing of urine and benefits the efficient chronic kidney disease management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China.
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310027, China.
- College of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
- Binjiang Institute of Zhejiang University, Hangzhou 310053, China.
ORCID-Profile: Xuesong Ye, Bo Liang
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Zhejiang Province, China
- Key Research and Development Program of Zhejiang Province, China
- 2022C03002); the Fundamental Research Funds for the Central Universities; Zhejiang University K.P.Chao's High Technology Development Foundation
- Fundamental Research Funds for the Central Universities
- Zhejiang University K.P.Chao’s High Technology Development Foundation
Zitieren
APA
Wang, D., Mao, X., Liang, Y., Cai, Y., Tu, T., Zhang, S., Li, T., Fang, L., Zhou, Y., Wang, Z., Jiang, Y., Ye, X., & Liang, B. (2023). Multi-Parameter Detection of Urine Based on Electropolymerized PANI: PSS/AuNPs/SPCE. Biosensors, 13(2), 272. https://doi.org/10.3390/bios13020272
Vancouver
Wang D, Mao X, Liang Y, Cai Y, Tu T, Zhang S, et al. Multi-Parameter Detection of Urine Based on Electropolymerized PANI: PSS/AuNPs/SPCE. Biosensors. 2023;13(2):272. doi:10.3390/bios13020272
BibTeX
@article{Wang2023,
author = {Wang, Dong and Mao, Xiyu and Liang, Yitao and Cai, Yu and Tu, Tingting and Zhang, Shanshan and Li, Tianyu and Fang, Lu and Zhou, Yue and Wang, Zhaoyang and Jiang, Yu and Ye, Xuesong and Liang, Bo},
title = {Multi-Parameter Detection of Urine Based on Electropolymerized PANI: PSS/AuNPs/SPCE},
journal = {Biosensors},
year = {2023},
volume = {13},
number = {2},
pages = {272},
doi = {10.3390/bios13020272}
}
EUVIMED