Factors Affecting the Mechanical Properties of Biomimetic Schwarz Primitive TPMS Structures Printed from Glass-Filled Polyamide: A Multivariate Regression Analysis
Biomimetics · 23.11.2026 · 11 (12) · 853
DOI: 10.3390/biomimetics11120853 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomimetics, online erschienen am 23.11.2026. Verfasst von Sergey Balabanov und 7 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Assignment, Russian Science Foundation.
Abstract (Originalsprache)
Triply periodic minimal surface (TPMS) structures have attracted considerable attention as lightweight architected materials for energy absorption and load-bearing applications. However, the combined influence of relative density and surface curvature on the mechanical behavior of glass-filled polyamide TPMS structures fabricated by selective laser sintering (SLS) remains insufficiently understood. In this study, biomimetic Schwarz Primitive TPMS structures with different values of the geometric parameter t were manufactured by SLS and experimentally investigated under quasi-static compression. The relationships between surface geometry, relative density, deformation behavior, mechanical properties, and energy absorption were analyzed. The results demonstrate that, in addition to relative density, the absolute value of the average signed curvature is associated with changes in the elastic modulus, compressive strength, deformation mode, and energy absorption capability of the structures. A structural approach for evaluating the effective plasticity of cellular materials based on their deformation behavior is proposed. Specimens with t values close to zero exhibited stable progressive collapse characterized by an extended stress plateau, whereas the maximum volumetric energy absorption (1.814 MJ/m3) was obtained for the structure with t = 0.3. In contrast, the structure with t = 0.9 exhibited premature failure at a limiting strain of 12.5% without reaching the densification stage. Comparison of experimental measurements with numerical homogenization revealed a systematic underestimation of Young’s modulus by the numerical model. Following calibration against the experimental reference configuration, a multivariate regression analysis was performed to quantify the relative contributions of relative density and absolute value of the average signed curvature to the effective Young’s modulus of SLS-printed glass-filled polyamide TPMS structures. The standardized regression coefficients indicated that, for the investigated SLS-printed glass-filled polyamide TPMS structures, the association between the absolute value of the average signed curvature and Young’s modulus was approximately 3.65 times stronger than that between relative density and Young’s modulus within the investigated dataset. Additional numerical homogenization analysis of the Gyroid topology was performed to examine the consistency of this relationship across different TPMS architectures. The results obtained provide practical guidelines for optimizing TPMS architectures with respect to strength, weight, and specific energy absorption, highlighting their potential for lightweight engineering and protective applications.
Förderung
- State Assignment
- Russian Science Foundation
Zitieren
APA
Balabanov, S., Dyachenko, S., Sysoev, E., Shulga, I., Arsentev, M., Sychev, M., Nosonovsky, M., & Skorb, E. (2026). Factors Affecting the Mechanical Properties of Biomimetic Schwarz Primitive TPMS Structures Printed from Glass-Filled Polyamide: A Multivariate Regression Analysis. Biomimetics, 11(12), 853. https://doi.org/10.3390/biomimetics11120853
Vancouver
Balabanov S, Dyachenko S, Sysoev E, Shulga I, Arsentev M, Sychev M, et al. Factors Affecting the Mechanical Properties of Biomimetic Schwarz Primitive TPMS Structures Printed from Glass-Filled Polyamide: A Multivariate Regression Analysis. Biomimetics. 2026;11(12):853. doi:10.3390/biomimetics11120853
BibTeX
@article{Balabanov2026,
author = {Balabanov, Sergey and Dyachenko, Semen and Sysoev, Evgenii and Shulga, Igor and Arsentev, Maxim and Sychev, Maxim and Nosonovsky, Michael and Skorb, Ekaterina},
title = {Factors Affecting the Mechanical Properties of Biomimetic Schwarz Primitive TPMS Structures Printed from Glass-Filled Polyamide: A Multivariate Regression Analysis},
journal = {Biomimetics},
year = {2026},
volume = {11},
number = {12},
pages = {853},
doi = {10.3390/biomimetics11120853}
}