EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors

Saikat Sahoo, Yoosun Kim, Dongmin Go, Sejun Park, Jeongho Choo, Gyeongmo Kim, Cheonkyu Park, Giuk Lee

Biomimetics · 01.11.2026 · 11 (11) · 782

DOI: 10.3390/biomimetics11110782 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 01.11.2026. Verfasst von Saikat Sahoo und 7 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea government.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human-in-the-loop (HITL) optimization can personalize exosuit assistance, but respirometry-based cost functions require bulky equipment, and proxy-based alternatives often require additional sensors or leave their relationship with metabolism unquantified. Our previous onboard-sensor approach optimized a single objective based on positive mechanical power (PMP). This exploratory study investigated whether stride time (ST), a gait response measured by the exosuit’s thigh-mounted inertial sensors, better represents metabolic reduction. Using grid-search data from three participants walking at 1 m/s on a 5° incline with a hip extension exosuit (six subject-day cases), we evaluated PMP, ST, and their combination by multiple linear regression, termed the multi-variable cost function (MVCF), with leave-one-subject-out cross-validation. ST predicted metabolic reduction numerically better than PMP (r = 0.63 ± 0.14 vs. 0.51 ± 0.37), and the MVCF performed best (r = 0.68 ± 0.11; lowest mean absolute error), although no difference was statistically significant. The MVCF, computed solely from onboard sensors, served as the objective of Bayesian HITL optimization in five participants. The optimized assistance significantly reduced net metabolic rate by 13.3%, 7.5%, and 5.2% versus power-off, no-suit, and biomimetic conditions, respectively. Combining device-side mechanical power with human-side gait timing may provide an onboard-sensor cost function grounded in measured metabolic data.

Förderung

  • National Research Foundation of Korea
  • Korea government

Zitieren

APA

Sahoo, S., Kim, Y., Go, D., Park, S., Choo, J., Kim, G., Park, C., & Lee, G. (2026). Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors. Biomimetics, 11(11), 782. https://doi.org/10.3390/biomimetics11110782

Vancouver

Sahoo S, Kim Y, Go D, Park S, Choo J, Kim G, et al. Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors. Biomimetics. 2026;11(11):782. doi:10.3390/biomimetics11110782

BibTeX
@article{Sahoo2026,
  author = {Sahoo, Saikat and Kim, Yoosun and Go, Dongmin and Park, Sejun and Choo, Jeongho and Kim, Gyeongmo and Park, Cheonkyu and Lee, Giuk},
  title = {Human-in-the-Loop Hip Exosuit Optimization for Uphill Walking: Stride Time and Mechanical Power from Onboard Sensors},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {11},
  pages = {782},
  doi = {10.3390/biomimetics11110782}
}
Kostenlos starten →