EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Structural Motifs as Programmable Design Parameters for Tuning Vascular Mechanics in Fiber-Reinforced Hydrogel Grafts

Dekel Maroz iD, Adi Aharonov, Hod Hoenig, Mirit Sharabi iD

Biomimetics · 19.08.2026 · 11 (8) · 591

DOI: 10.3390/biomimetics11080591 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 19.08.2026. Verfasst von Dekel Maroz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 407000, Israel. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Innovation, Science and Technology, Israeli Ministry of Innovation, Science, and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Replicating the nonlinear, pressure-dependent mechanical behavior of native arteries remains a central challenge in small-diameter vascular graft design, where compliance mismatch between synthetic grafts and host vessels is strongly linked to graft failure. Building on a silk fiber-reinforced alginate–polyacrylamide interpenetrating polymer network (IPN) hydrogel platform, we investigated whether biomimetic vascular structural motifs, specifically fiber reorientation and crimp, can be used as programmable design parameters to tune the tensile and pressure-dependent mechanical response of tubular constructs toward native coronary artery behavior. Three architectures were fabricated: a cross-plied (CP) baseline, a 25° reoriented configuration, and a crimped CP configuration. Under internal pressurization, fiber reorientation and crimp significantly increased compliance at low physiological pressures, with a consistent directional trend across the full pressure range, by extending the low-stiffness toe region preceding fiber recruitment while preserving tensile stiffness. Across the investigated pressure range, all architectures exhibited compliance within the reported range of native coronary arteries, with crimped constructs producing pressure–diameter behavior that most closely resembled young coronary arteries, whereas the CP baseline more closely resembled aged coronary arteries. These findings demonstrate that biomimetic structural motifs, without altering material composition, can serve as programmable design parameters for engineering vascular mechanics, enabling a single material platform to reproduce distinct physiological mechanical phenotypes through architecture alone.

Schlagwörter

Stichwörter der Autor:innen

biomimetic designcompliance matchingfiber-reinforced hydrogelsnonlinear mechanicssoft compositesstructural motifsvascular grafts

Autor:innen und Institutionen

  • Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 407000, Israel.

ORCID-Profile: Dekel Maroz, Mirit Sharabi

Förderung

  • Ministry of Innovation, Science and Technology
  • Israeli Ministry of Innovation, Science, and Technology

Zitieren

APA

Maroz, D., Aharonov, A., Hoenig, H., & Sharabi, M. (2026). Structural Motifs as Programmable Design Parameters for Tuning Vascular Mechanics in Fiber-Reinforced Hydrogel Grafts. Biomimetics, 11(8), 591. https://doi.org/10.3390/biomimetics11080591

Vancouver

Maroz D, Aharonov A, Hoenig H, Sharabi M. Structural Motifs as Programmable Design Parameters for Tuning Vascular Mechanics in Fiber-Reinforced Hydrogel Grafts. Biomimetics. 2026;11(8):591. doi:10.3390/biomimetics11080591

BibTeX
@article{Maroz2026,
  author = {Maroz, Dekel and Aharonov, Adi and Hoenig, Hod and Sharabi, Mirit},
  title = {Structural Motifs as Programmable Design Parameters for Tuning Vascular Mechanics in Fiber-Reinforced Hydrogel Grafts},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {8},
  pages = {591},
  doi = {10.3390/biomimetics11080591}
}
Kostenlos starten →