EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Standardized Testing and Quantitative Safety Assessment for Upper Limb Rehabilitation Robots: A Bionic Robotic Platform and Integrated Evaluation Framework

Yuheng Jiang, Yanchen Du, Shengli Luo, Xiaolong Shu, Qingzhuo Yuan, Hongliu Yu

Biomimetics · 01.07.2026 · 11 (7) · 456

DOI: 10.3390/biomimetics11070456 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 01.07.2026. Verfasst von Yuheng Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the lack of standardized safety assessment tools for upper-limb rehabilitation robots, this study developed an integrated testing platform and a quantitative safety assessment framework, demonstrated with FlexoArm1 as a proof-of-concept. A 6-degree-of-freedom bionic arm equipped with multiple sensors was constructed, and a fuzzy PID control algorithm was employed to improve motion trajectory tracking accuracy. A fuzzy multi-criteria safety assessment model was established by combining the Analytic Hierarchy Process (AHP) with the entropy weight method. Experiments were conducted on the rehabilitation robot FlexoArm1. The platform reliably replaced human subjects in range-of-motion testing, interactive torque measurement (peak torque approximately 6.2 N·m in fully active mode), and spasticity simulation, with angular data showing close agreement with Inertial Measurement Unit (IMU) measurements. The assessment model assigned a comprehensive safety score of 70.23 to the tested device, successfully identifying weaknesses in fault detection capability and structural safety design. The proposed bionic-arm-based testing platform and the accompanying safety assessment methodology provide practical tools and a quantitative basis for standardizing safety evaluation and guiding design optimization of upper-limb rehabilitation robots.

Schlagwörter

Stichwörter der Autor:innen

bionic upper limbcontrol system frameworksafety assessmenttesting platformupper limb rehabilitation robot

Autor:innen und Institutionen

  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Shanghai Engineering Research Center of Assistive Devices, Shanghai 200093, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Jiang, Y., Du, Y., Luo, S., Shu, X., Yuan, Q., & Yu, H. (2026). Standardized Testing and Quantitative Safety Assessment for Upper Limb Rehabilitation Robots: A Bionic Robotic Platform and Integrated Evaluation Framework. Biomimetics, 11(7), 456. https://doi.org/10.3390/biomimetics11070456

Vancouver

Jiang Y, Du Y, Luo S, Shu X, Yuan Q, Yu H. Standardized Testing and Quantitative Safety Assessment for Upper Limb Rehabilitation Robots: A Bionic Robotic Platform and Integrated Evaluation Framework. Biomimetics. 2026;11(7):456. doi:10.3390/biomimetics11070456

BibTeX
@article{Jiang2026,
  author = {Jiang, Yuheng and Du, Yanchen and Luo, Shengli and Shu, Xiaolong and Yuan, Qingzhuo and Yu, Hongliu},
  title = {Standardized Testing and Quantitative Safety Assessment for Upper Limb Rehabilitation Robots: A Bionic Robotic Platform and Integrated Evaluation Framework},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {7},
  pages = {456},
  doi = {10.3390/biomimetics11070456}
}
Kostenlos starten →