Adversarial CAM Guidance for Chest X-Ray Classification: Reducing Framing Sensitivity with Mask Supervision
Biomimetics · 10.06.2026 · 11 (6) · 409
DOI: 10.3390/biomimetics11060409 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomimetics, online erschienen am 10.06.2026. Verfasst von Ganbayar Batchuluun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Electronics and Electrical Engineering, Dongguk University, 30 Pildong-ro 1gil, Jung-gu, Seoul 04620, Republic of Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, Artificial Intelligence Convergence Innovation Human Resources Development.
Abstract (Originalsprache)
The deep classifiers used for chest X-ray diagnosis can be sensitive to the visual frame around the evidence, producing correct labels for the wrong reasons by relying on the background, borders, text marks, or acquisition artifacts. This framing sensitivity reduces their trustworthiness, and they can fail under a distribution shift. Inspired by biological vision, especially figure–ground segregation and selective attention, we propose a bio-inspired adversarial attention alignment training process that encourages evidence-centered decisions without changing the classifier structure. A classifier is first trained with image-level labels. Class activation mapping (CAM) is then used to produce a differentiable heatmap that indicates where the model attends. We treat this heatmap as a generated localization map and train a discriminator to distinguish the generated heatmaps from ground truth masks. The classifier is updated using a joint objective that preserves the classification performance while pushing its CAM heatmap toward a mask-like structure, reducing the reliance on background cues. We also introduce evaluation measures for the test phase, including augmentation inconsistency (prediction flip rate under angle-based augmentations) and framing sensitivity (CAM energy outside the mask). The experiments show improved lung-focused attention and robustness, while requiring masks only during training and no additional inputs at inference.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Electronics and Electrical Engineering, Dongguk University, 30 Pildong-ro 1gil, Jung-gu, Seoul 04620, Republic of Korea.
Förderung
- Ministry of Science and ICT
- Artificial Intelligence Convergence Innovation Human Resources Development
Zitieren
APA
Batchuluun, G., Lee, S. J., Im, S. J., & Park, K. R. (2026). Adversarial CAM Guidance for Chest X-Ray Classification: Reducing Framing Sensitivity with Mask Supervision. Biomimetics, 11(6), 409. https://doi.org/10.3390/biomimetics11060409
Vancouver
Batchuluun G, Lee SJ, Im SJ, Park KR. Adversarial CAM Guidance for Chest X-Ray Classification: Reducing Framing Sensitivity with Mask Supervision. Biomimetics. 2026;11(6):409. doi:10.3390/biomimetics11060409
BibTeX
@article{Batchuluun2026,
author = {Batchuluun, Ganbayar and Lee, Sung Jae and Im, Su Jin and Park, Kang Ryoung},
title = {Adversarial CAM Guidance for Chest X-Ray Classification: Reducing Framing Sensitivity with Mask Supervision},
journal = {Biomimetics},
year = {2026},
volume = {11},
number = {6},
pages = {409},
doi = {10.3390/biomimetics11060409}
}
EUVIMED