Fachartikel in der Zeitschrift Biomimetics, online erschienen am 03.06.2026. Verfasst von Alejandro A Salinas-Aguilar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tequexquite, Centro de Investigación y Desarrollo Tecnológico para la Accesibilidad e Innovación Social, Facultad de Ingeniería, Universidad Autónoma…. Die Arbeit nennt 90 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effective diabetes management heavily relies on appropriate insulin administration, which strongly depends on the correct administration strategy. In this sense, insulin administration plays a fundamental role, as its use depends on the patient’s clinical condition and diabetes type. Traditional syringe-based methods require proper training to ensure that insulin is successfully delivered into the subcutaneous tissue, where it can be absorbed and metabolized; however, it is desirable to develop an insulin applicator that does not require training for its appropriate use. Aiming to provide support solutions that help patients to develop a correct administration technique, a biodesign-based methodology, coupled with biomimetic concepts, is employed to design a device that assists the user in creating a stable skin fold and guiding needle orientation during injection without requiring exhaustive training for device usage. A three-step approach is employed for the design, where computational fluid dynamics (CFD) and finite element analysis (FEA) methods are employed to ensure that the device produces a laminar insulin flow and the device strength is tested. It should be pointed out both methods are required since complications produced by sudden flows must be avoided, with CFD allowing assessment of the device mechanical properties in terms of the device strength. Initial functional evaluation indicates that the proposed approach does not require extensive training or complex operational procedures, facilitating its integration into everyday use. The device design is validated from the results obtained for the CFD analysis, as no turbulent flow is produced, whereas the FEA indicates that the geometrical form can handle the stresses produced by the folding generation without generating excessive deformations. Moreover, an infrared thermography analysis is also carried out to find out if the folding force generation is located in the zone of interest, the results of which indicate that the device operates in the desired physical zone.

Schlagwörter

Stichwörter der Autor:innen

biodesign methodologyindustrial designinsuline applicator

Autor:innen und Institutionen

  • Tequexquite, Centro de Investigación y Desarrollo Tecnológico para la Accesibilidad e Innovación Social, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Campus Aeropuerto, Carretera a Chichimequillas S/N, Eji…

ORCID-Profile: Alejandro A Salinas-Aguilar, Carlos A Perez-Ramirez, Irving A Cruz-Albarran, Andres Emilio Hurtado-Perez, Manuel Toledano-Ayala

Zitieren

APA

Salinas-Aguilar, A. A., Arriaga-Marin, S., Perez-Ramirez, C. A., Cervantes-Gutierrez, I., Cruz-Albarran, I. A., Hurtado-Perez, A. E., & Toledano-Ayala, M. (2026). The Development of a Syringe-Based Insulin Applicator Using a Biodesign-Based Methodology. Biomimetics, 11(6), 394. https://doi.org/10.3390/biomimetics11060394

Vancouver

Salinas-Aguilar AA, Arriaga-Marin S, Perez-Ramirez CA, Cervantes-Gutierrez I, Cruz-Albarran IA, Hurtado-Perez AE, et al. The Development of a Syringe-Based Insulin Applicator Using a Biodesign-Based Methodology. Biomimetics. 2026;11(6):394. doi:10.3390/biomimetics11060394

BibTeX
@article{SalinasAguilar2026,
  author = {Salinas-Aguilar, Alejandro A and Arriaga-Marin, Sebastian and Perez-Ramirez, Carlos A and Cervantes-Gutierrez, Ignacio and Cruz-Albarran, Irving A and Hurtado-Perez, Andres Emilio and Toledano-Ayala, Manuel},
  title = {The Development of a Syringe-Based Insulin Applicator Using a Biodesign-Based Methodology},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {6},
  pages = {394},
  doi = {10.3390/biomimetics11060394}
}
Kostenlos starten →