EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparing Laboratory and Synchrotron X-Ray CT for Structural Analysis of PEEK Orthopedic Implants

Meili Qi iD, Yanwei Zhao, Jinwen Chen, Shengtao Zhang, Jie Zhang, Xu Zhang

Biomimetics · 21.05.2026 · 11 (5) · 357

DOI: 10.3390/biomimetics11050357 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 21.05.2026. Verfasst von Meili Qi und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering, Shandong Jiaotong University, Jinan 250357, China. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Young Talent of Lifting Engineering for Science and Technology in Shandong, China, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polyetheretherketone (PEEK) is widely employed in orthopedic applications due to its bone-mimetic mechanical properties and excellent biocompatibility, establishing it as a promising candidate for bone repair and regeneration. However, the investigation of structural integrity and microstructural features of PEEK implants has remained limited owing to its low atomic number (Z < 8) and hierarchical microstructure. This study presents a comparative characterization of PEEK implants by integrating laboratory X-ray computed tomography (CT) and synchrotron X-ray phase-contrast tomography (SXCT). Laboratory X-ray CT, operating on absorption contrast mechanisms, demonstrates adequate capacity for visualizing macroscopic defects and pore architectures, but exhibits limitations in resolving subtle density variations. In contrast, SXCT, employing phase-contrast imaging, significantly enhances discrimination of ultra-low-contrast features, including interconnected pore networks and localized density gradients. This work elucidates the complementary advantages and inherent limitations of both the imaging modalities for characterizing PEEK-based biomaterials. Furthermore, it demonstrates the potential extensibility of this comparative approach to other polymer composites, offering a methodology to investigate material–tissue interactions in orthopedic research and advancing the development of next-generation implantable devices.

Schlagwörter

Stichwörter der Autor:innen

X-ray CTbiomedical PEEK implantsedge enhancementorthopedic implant evaluation

Autor:innen und Institutionen

  • School of Civil Engineering, Shandong Jiaotong University, Jinan 250357, China.
  • Shandong Key Laboratory of Technologies and Systems for Intelligent Construction Equipment, Shandong Jiaotong University, Jinan 250357, China.
  • National United Engineering Laboratory for Biomedical Material Modification, Dezhou 251100, China.

ORCID-Profile: Meili Qi

Förderung

  • Young Talent of Lifting Engineering for Science and Technology in Shandong, China
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Qi, M., Zhao, Y., Chen, J., Zhang, S., Zhang, J., & Zhang, X. (2026). Comparing Laboratory and Synchrotron X-Ray CT for Structural Analysis of PEEK Orthopedic Implants. Biomimetics, 11(5), 357. https://doi.org/10.3390/biomimetics11050357

Vancouver

Qi M, Zhao Y, Chen J, Zhang S, Zhang J, Zhang X. Comparing Laboratory and Synchrotron X-Ray CT for Structural Analysis of PEEK Orthopedic Implants. Biomimetics. 2026;11(5):357. doi:10.3390/biomimetics11050357

BibTeX
@article{Qi2026,
  author = {Qi, Meili and Zhao, Yanwei and Chen, Jinwen and Zhang, Shengtao and Zhang, Jie and Zhang, Xu},
  title = {Comparing Laboratory and Synchrotron X-Ray CT for Structural Analysis of PEEK Orthopedic Implants},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {5},
  pages = {357},
  doi = {10.3390/biomimetics11050357}
}