A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors
Biomimetics · 31.03.2026 · 11 (4) · 229
DOI: 10.3390/biomimetics11040229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomimetics, online erschienen am 31.03.2026. Verfasst von Baozhen Ren und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, China. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Key Research and Development Program of China, Natural Science Foundation of Hebei Province, the Beijing-Tianjin-Hebei Basic Research Cooperation Project.
Abstract (Originalsprache)
Interventional robots play a crucial role in surgical procedures, where accurate force measurement is essential for enhancing safety. Compliant mechanisms utilize material deformation to achieve millinewton-scale force output and millimeter-level displacement with high repeatability. Motivated by this, we propose a method for measuring the catheter force by integrating a compliant mechanism and a sensor. First, we designed an operating force detection module. It comprises a double-parallelogram structure with four elastic units, a catheter drive module, and a sensor. The sensor connects the compliant mechanism to the base. Second, stiffness and gravity compensation models were established and validated experimentally. Finally, we constructed an experimental platform to evaluate the force measurement accuracy, drive accuracy, and real-time detection capability. Experimental results demonstrate that the proposed method achieves a maximum detection error of 0.1482 N, an average error of 0.0096 N, a resolution of 0.01 N, and an average axial delivery error of 0.8287 mm. Additionally, a master–slave control framework was developed, along with a master controller that manipulates the slave robot to deliver the catheter within a vascular phantom, while simultaneously displaying real-time force information via the human–computer interaction interface.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, China.
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China.
ORCID-Profile: Baozhen Ren, Yongliang Cao
Förderung
- the National Key Research and Development Program of China
- Natural Science Foundation of Hebei Province
- the Beijing-Tianjin-Hebei Basic Research Cooperation Project
- National Key Research and Development Program of China
- Beijing-Tianjin-Hebei Basic Research Cooperation Project
- Beijing Natural Science Foundation
Zitieren
APA
Ren, B., Li, H., Cao, Y., Wang, C., Zhao, Y., & Zhang, J. (2026). A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors. Biomimetics, 11(4), 229. https://doi.org/10.3390/biomimetics11040229
Vancouver
Ren B, Li H, Cao Y, Wang C, Zhao Y, Zhang J. A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors. Biomimetics. 2026;11(4):229. doi:10.3390/biomimetics11040229
BibTeX
@article{Ren2026,
author = {Ren, Baozhen and Li, Hui and Cao, Yongliang and Wang, Chang and Zhao, Yan and Zhang, Jianhua},
title = {A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors},
journal = {Biomimetics},
year = {2026},
volume = {11},
number = {4},
pages = {229},
doi = {10.3390/biomimetics11040229}
}
EUVIMED