EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design of Adaptive LQR Control Based on Improved Grey Wolf Optimization for Prosthetic Hand

Khaled Ahmed iD, Ayman A Aly iD, Mohamed O Elhabib iD

Biomimetics · 30.06.2025 · 10 (7) · 423

DOI: 10.3390/biomimetics10070423 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 30.06.2025. Verfasst von Khaled Ahmed und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Salman center For Disability Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Assistive technologies, particularly multi-fingered robotic hands (MFRHs), are critical for enhancing the quality of life for individuals with upper-limb disabilities. However, achieving precise and stable control of such systems remains a significant challenge. This study proposes an Improved Grey Wolf Optimization (IGWO)-tuned Linear Quadratic Regulator (LQR) to enhance the control performance of an MFRH. The MFRH was modeled using Denavit–Hartenberg kinematics and Euler–Lagrange dynamics, with micro-DC motors selected based on computed torque requirements. The LQR controller, optimized via IGWO to systematically determine weighting matrices, was benchmarked against PID and PID-PSO controllers under diverse input scenarios. For step input, the IGWO-LQR achieved a settling time of 0.018 s with zero overshoot for Joint 1, outperforming PID (settling time: 0.0721 s; overshoot: 6.58%) and PID-PSO (settling time: 0.042 s; overshoot: 2.1%). Similar improvements were observed across all joints, with Joint 3 recording an IAE of 0.001334 for IGWO-LQR versus 0.004695 for PID. Evaluations under square-wave, sine, and sigmoid inputs further validated the controller’s robustness, with IGWO-LQR consistently delivering minimal tracking errors and rapid stabilization. These results demonstrate that the IGWO-LQR framework significantly enhances precision and dynamic response.

Schlagwörter

Stichwörter der Autor:innen

IGWOdisabled peopleoptimal controlprosthetic hand

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • King Salman Center for Disability Research, Riyadh 11614, Saudi Arabia.
  • Department of Mechanical Engineering, College of Engineering, Taif University, Taif 21944, Saudi Arabia.
  • Control and Mechatronics Engineering Division, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Malaysia.

ORCID-Profile: Khaled Ahmed, Ayman A Aly, Mohamed O Elhabib

Förderung

  • King Salman center For Disability Research

Zitieren

APA

Ahmed, K., Aly, A. A., & Elhabib, M. O. (2025). Design of Adaptive LQR Control Based on Improved Grey Wolf Optimization for Prosthetic Hand. Biomimetics, 10(7), 423. https://doi.org/10.3390/biomimetics10070423

Vancouver

Ahmed K, Aly AA, Elhabib MO. Design of Adaptive LQR Control Based on Improved Grey Wolf Optimization for Prosthetic Hand. Biomimetics. 2025;10(7):423. doi:10.3390/biomimetics10070423

BibTeX
@article{Ahmed2025,
  author = {Ahmed, Khaled and Aly, Ayman A and Elhabib, Mohamed O},
  title = {Design of Adaptive LQR Control Based on Improved Grey Wolf Optimization for Prosthetic Hand},
  journal = {Biomimetics},
  year = {2025},
  volume = {10},
  number = {7},
  pages = {423},
  doi = {10.3390/biomimetics10070423}
}