EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Luminex MFI—Efforts from a Qualitative to a Quantitative Analysis

Thomas Schacker, Ramona Landgraf, Ilias Doxiadis, Henry Loeffler-Wirth iD, Claudia Lehmann iD

Biology · 12.06.2025 · 14 (6) · 686

DOI: 10.3390/biology14060686 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biology, online erschienen am 12.06.2025. Verfasst von Thomas Schacker und 4 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Centre for Bioinformatics, IZBI, Leipzig University, 04107 Leipzig, Germany. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Luminex multiplex assay for the definition of HLA antibodies was introduced 20 years ago. To date, although the assay is simple and straightforward, the interpretation of the results remains a conundrum. Making use of the so-called mean fluorescence value only does not help since this value is relative, the day-to-day variation is significantly large, and the user variation is beyond acceptable ranges. Within the same range of problems, the cutoff value used to classify HLA-specific antibodies as being either present or absent varies between laboratories. This threshold influences clinical decision-making. In addition, the readout value is used to diagnose the amount of HLA-specific antibodies after treatments like absorption, plasmapheresis, or transplantation, overlooking the relative nature of the value. In this study, we show bead variability for HLA class I and HLA class II based on negatively defined bead reactions with a mean fluorescence value below 1500 and self-antigens. In an effort to circumvent the assay’s inherent problems, we introduced the term ratio. For each serum sample, a paired sample from before the treatment is run in parallel. The ratio of post-treatment to pre-treatment can then be used to characterize antibody dynamics: a ratio above 1 reflects increased antibody production and a ratio below 1 indicates a decrease in antibodies in the serum. This value may offer the possibility to make more informed and adaptive treatment decisions.

Schlagwörter

Stichwörter der Autor:innen

HLA antibodiesLuminexMFIbead variabilitybead-based solid phaseratio

Autor:innen und Institutionen

  • Interdisciplinary Centre for Bioinformatics, IZBI, Leipzig University, 04107 Leipzig, Germany.
  • Laboratory for Transplantation Immunology, Institute for Transfusion Medicine, University Hospital Leipzig, 04103 Leipzig, Germany.
  • HLA Laboratory, Institute for Transfusion Medicine, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany.

ORCID-Profile: Henry Loeffler-Wirth, Claudia Lehmann

Zitieren

APA

Schacker, T., Landgraf, R., Doxiadis, I., Loeffler-Wirth, H., & Lehmann, C. (2025). Luminex MFI—Efforts from a Qualitative to a Quantitative Analysis. Biology, 14(6), 686. https://doi.org/10.3390/biology14060686

Vancouver

Schacker T, Landgraf R, Doxiadis I, Loeffler-Wirth H, Lehmann C. Luminex MFI—Efforts from a Qualitative to a Quantitative Analysis. Biology. 2025;14(6):686. doi:10.3390/biology14060686

BibTeX
@article{Schacker2025,
  author = {Schacker, Thomas and Landgraf, Ramona and Doxiadis, Ilias and Loeffler-Wirth, Henry and Lehmann, Claudia},
  title = {Luminex MFI—Efforts from a Qualitative to a Quantitative Analysis},
  journal = {Biology},
  year = {2025},
  volume = {14},
  number = {6},
  pages = {686},
  doi = {10.3390/biology14060686}
}
Kostenlos starten →