EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Efficient and Enhanced Signal Quality Assessment for EDA Wearables

Luoluo Liu, Linda M. Eerikäinen, Octavian Cota, Nicholas Huang, Mark van Gastel

Bioengineering · 19.11.2026 · 13 (11) · 1388

DOI: 10.3390/bioengineering13111388 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 19.11.2026. Verfasst von Luoluo Liu und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrodermal activity (EDA) is a widely used marker of sympathetic arousal and stress, in both daily-life and clinical monitoring, but EDA signals from wearable devices are frequently degraded by artifacts, and expert-labeled data for quality assessment are scarce. We present a lightweight EDA signal quality index (SQI) system that uses unsupervised pre-training to reduce reliance on labeled data. The model is first pre-trained on unsupervised denoising and forecasting tasks, then fine-tuned using a publicly available expert-labeled dataset. On the EDABE benchmark, our method achieves a mean ROC-AUC of 0.851 and a mean AUPRC of 0.494, improvements of 8% and 18.5%, respectively, over the strongest baseline. The model also generalizes across devices, body locations, and types of motion: applied zero-shot to AffectiveROAD, wrist-worn Empatica E4 recordings from real-world driving (whereas training used finger-worn sensors), it achieves a ROC-AUC of 0.740, a 7.9% improvement over the same network trained from scratch, using high wrist acceleration as the reference for motion artifacts. The model requires 3.9 MFLOPs per inference. These results show that unsupervised pre-training improves performance, enabling scalable, low-power EDA quality assessment for continuous wearable monitoring.

Zitieren

APA

Liu, L., Eerikäinen, L. M., Cota, O., Huang, N., & Gastel, M. V. (2026). Efficient and Enhanced Signal Quality Assessment for EDA Wearables. Bioengineering, 13(11), 1388. https://doi.org/10.3390/bioengineering13111388

Vancouver

Liu L, Eerikäinen LM, Cota O, Huang N, Gastel MV. Efficient and Enhanced Signal Quality Assessment for EDA Wearables. Bioengineering. 2026;13(11):1388. doi:10.3390/bioengineering13111388

BibTeX
@article{Liu2026,
  author = {Liu, Luoluo and Eerikäinen, Linda M. and Cota, Octavian and Huang, Nicholas and Gastel, Mark van},
  title = {Efficient and Enhanced Signal Quality Assessment for EDA Wearables},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {11},
  pages = {1388},
  doi = {10.3390/bioengineering13111388}
}
Kostenlos starten →