EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of a Topical Hemostatic Dressing (WoundClot®) for Aerostasis Following Pulmonary Resection: An Ex Vivo Porcine Lung Model Study

George-Bucur Delaca, Ioana-Medeea Titu, Andreea Mironică, Gabriel Kacsó, Emanuel Palade

Bioengineering · 19.11.2026 · 13 (11) · 1383

DOI: 10.3390/bioengineering13111383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 19.11.2026. Verfasst von George-Bucur Delaca und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air leaks remain a common complication following pulmonary resections and can significantly impact postoperative outcomes. This experimental study aimed to evaluate the efficacy of WoundClot®, a topical hemostatic agent, in achieving aerostasis following non-anatomical lung resections in an ex vivo porcine lung model. Twenty fresh porcine pulmonary lobes were used. Each lobe underwent a standardized wedge resection using monopolar electrocautery. The airtightness of the defect was assessed using a submersion test. Subsequently, a 10 × 10 cm WoundClot® dressing was applied directly over the same defect, followed by reassessment. Burst pressure was measured by gradually increasing the inspiratory pressure until the first sign of air leakage (appearance of escaping air bubbles) occurred. Airtightness was scored using a standardized 4-point scale. Data were analyzed using the paired Student’s t-test and Wilcoxon signed-rank test. WoundClot® significantly improved both airtightness scores (p = 0.001) and burst pressure values (p = 0.013) compared to control. The dressing provided effective sealing of the resection site under simulated intraoperative pressures, with results comparable to previously reported sealants in similar models. WoundClot® demonstrated promising performance as a topical agent for sealing air leaks in a porcine lung model, supporting its potential applicability in pulmonary resections.

Zitieren

APA

Delaca, G., Titu, I., Mironică, A., Kacsó, G., & Palade, E. (2026). Evaluation of a Topical Hemostatic Dressing (WoundClot®) for Aerostasis Following Pulmonary Resection: An Ex Vivo Porcine Lung Model Study. Bioengineering, 13(11), 1383. https://doi.org/10.3390/bioengineering13111383

Vancouver

Delaca G, Titu I, Mironică A, Kacsó G, Palade E. Evaluation of a Topical Hemostatic Dressing (WoundClot®) for Aerostasis Following Pulmonary Resection: An Ex Vivo Porcine Lung Model Study. Bioengineering. 2026;13(11):1383. doi:10.3390/bioengineering13111383

BibTeX
@article{Delaca2026,
  author = {Delaca, George-Bucur and Titu, Ioana-Medeea and Mironică, Andreea and Kacsó, Gabriel and Palade, Emanuel},
  title = {Evaluation of a Topical Hemostatic Dressing (WoundClot®) for Aerostasis Following Pulmonary Resection: An Ex Vivo Porcine Lung Model Study},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {11},
  pages = {1383},
  doi = {10.3390/bioengineering13111383}
}
Kostenlos starten →