Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA)
Bioengineering · 17.11.2026 · 13 (11) · 1372
DOI: 10.3390/bioengineering13111372 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Bioengineering, online erschienen am 17.11.2026. Verfasst von Maurizio Ledda und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Composite attachments are widely used to improve tooth-movement expression in clear aligner therapy, yet the influence of attachment morphology and position remains uncertain. This systematic review synthesised finite element analysis (FEA) evidence on how attachment shape and placement affect the initial biomechanical expression of programmed tooth movement, using the no-attachment (NA) condition as the primary comparator.
Methods
Following the PRISMA 2020 statement and a PROSPERO-registered protocol (CRD420261414416), five databases (PubMed, Embase, Scopus, Web of Science, and Cochrane CENTRAL) were searched. FEA studies including an NA condition and evaluating at least one target movement, rotation, molar distalization/mesialization, torque, intrusion, or extrusion; clinical, typodont, and in vitro studies, were excluded. Eighteen studies (2019–2026; seven countries) were included in a qualitative synthesis. Risk of bias was appraised with ROBFEAD, the validated Risk of Bias tool for Finite Element Analysis in Dentistry.
Results
The NA condition frequently, but not uniformly, produced lower initial target-tooth displacement than the attachment conditions, but the magnitude and direction of the attachment effect suggested a movement-dependent pattern: attachments appeared essential for extrusion, less consistent for intrusion and molar movement, and least determinative for small incisor torque. Among the shapes tested, horizontal rectangular, vertical rectangular and semi-ellipsoidal designs were those most often reported as best performing, although this reflects which shapes each study chose to model.
Conclusions
In FEA models, composite attachments frequently, but not uniformly, enhanced the initial biomechanical expression of programmed movements, in a movement-dependent manner. As finite element outputs reflect initial displacement and stress rather than achieved clinical movement. These findings are hypothesis-generating and are further constrained by the frequent confounding of attachment shape with position.
Zitieren
APA
Ledda, M., Verdecchia, A., Dettori, F. B., Carboni, L., Cabras, S., Garau, V., & Spinas, E. (2026). Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA). Bioengineering, 13(11), 1372. https://doi.org/10.3390/bioengineering13111372
Vancouver
Ledda M, Verdecchia A, Dettori FB, Carboni L, Cabras S, Garau V, et al. Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA). Bioengineering. 2026;13(11):1372. doi:10.3390/bioengineering13111372
BibTeX
@article{Ledda2026,
author = {Ledda, Maurizio and Verdecchia, Alessio and Dettori, Francesco Bustio and Carboni, Laura and Cabras, Serena and Garau, Valentino and Spinas, Enrico},
title = {Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA)},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {11},
pages = {1372},
doi = {10.3390/bioengineering13111372}
}
EUVIMED