In Vitro Hemodynamic Assessment of a Novel Pulmonary Visceral Pleura (PVP) Transcatheter Aortic Valve Replacement Prototype Based on Optical and Acoustic Measurements
Bioengineering · 07.11.2026 · 13 (11) · 1323
DOI: 10.3390/bioengineering13111323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 07.11.2026. Verfasst von Colten Alme und 4 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Heart, Lung, and Blood Institute of the National Institutes of Health, National Science Foundation.
Abstract (Originalsprache)
Structural valve degradation remains a key limitation of bioprosthetic transcatheter aortic valve replacement (TAVR) devices, whose bovine or porcine pericardium leaflets are prone to calcification and long-term failure. Pulmonary visceral pleura (PVP), a thin, elastin-rich tissue, has emerged as a promising alternative leaflet material. This study presents an in vitro hemodynamic evaluation of a prototype PVP valve under physiologically representative pulsatile flow in a custom benchtop flow loop. A multimodal framework combined four techniques: high-speed imaging with U-Net deep learning segmentation of the geometric orifice area, quantitative Doppler velocity extraction developed on a Verasonics research ultrasound platform, double-pulse particle image velocimetry (PIV) of the downstream flow field, and transvalvular pressure measurement. The PVP valve was compared with a stiff silicone valve representing a stenotic reference condition. At 75 bpm and 5 L/min, the PVP valve reached a peak geometric orifice area of 2.91 cm2, a mean pressure gradient of 4.3 mmHg, and a peak jet velocity of 2.46 m/s, meeting the ASE velocity and gradient criteria for normal prosthetic valve function. The silicone valve opened to 1.1 cm2 with a gradient of 36.9 mmHg, consistent with moderate-to-severe stenosis. The framework provides a basis for characterizing new bioprosthetic valve materials and benchmark data for fluid–structure interaction modeling.
Förderung
- National Heart, Lung, and Blood Institute of the National Institutes of Health
- National Science Foundation
Zitieren
APA
Alme, C., Golder, S., Lu, X., Luo, H., & Zhang, Y. (2026). In Vitro Hemodynamic Assessment of a Novel Pulmonary Visceral Pleura (PVP) Transcatheter Aortic Valve Replacement Prototype Based on Optical and Acoustic Measurements. Bioengineering, 13(11), 1323. https://doi.org/10.3390/bioengineering13111323
Vancouver
Alme C, Golder S, Lu X, Luo H, Zhang Y. In Vitro Hemodynamic Assessment of a Novel Pulmonary Visceral Pleura (PVP) Transcatheter Aortic Valve Replacement Prototype Based on Optical and Acoustic Measurements. Bioengineering. 2026;13(11):1323. doi:10.3390/bioengineering13111323
BibTeX
@article{Alme2026,
author = {Alme, Colten and Golder, Santu and Lu, Xiao and Luo, Haoxiang and Zhang, Yan},
title = {In Vitro Hemodynamic Assessment of a Novel Pulmonary Visceral Pleura (PVP) Transcatheter Aortic Valve Replacement Prototype Based on Optical and Acoustic Measurements},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {11},
pages = {1323},
doi = {10.3390/bioengineering13111323}
}
EUVIMED