EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis

Hilal Algül, Mahzun Yıldız, Eda Gürbüz Dinç, Ferit Dinç, Kaan Orhan, Ayşe Tuba Altuğ

Bioengineering · 07.11.2026 · 13 (11) · 1319

DOI: 10.3390/bioengineering13111319 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 07.11.2026. Verfasst von Hilal Algül und 5 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Ertty Gap III appliance has been proposed for the orthopaedic treatment of growing patients with skeletal Class III malocclusion. This study aimed to characterise its modelled mechanical response under a hypothetical force-controlled loading configuration, rather than to reproduce clinical screw activation. A three-dimensional finite element model was constructed by combining craniofacial geometry reconstructed from the CBCT data of a 12-year-old female patient with independently digitised extracted human teeth. A digitised Ertty Gap III appliance was incorporated, and bilateral forces of 1.5 N at the first-molar hooks and an anteriorly directed force of 10 N at the inverted HYRAX® screw body were prescribed. The 10-N force was not calibrated to a 0.25-mm screw opening. Stress, strain, and displacement were evaluated under static and cyclic loading. The mechanical response was concentrated in the premaxillary and anterior maxillary regions, with localised stress and strain around the premaxillary–maxillary suture. Across six anatomical probe locations, von Mises stress ranged from 0.002 to 0.175 MPa, with the highest sampled value recorded in the central incisor alveolar cortex. The highest sampled resultant displacement was approximately 0.013 mm at the anterior premaxillary cortex. Under cyclic loading, the response remained predominantly anterior, with posterior anchorage and dentoalveolar involvement. These findings describe the mechanical response to the prescribed forces under the adopted modelling assumptions. They do not establish the response to a specified HYRAX® opening or demonstrate clinical skeletal correction.

Zitieren

APA

Algül, H., Yıldız, M., Dinç, E. G., Dinç, F., Orhan, K., & Altuğ, A. T. (2026). Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis. Bioengineering, 13(11), 1319. https://doi.org/10.3390/bioengineering13111319

Vancouver

Algül H, Yıldız M, Dinç EG, Dinç F, Orhan K, Altuğ AT. Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis. Bioengineering. 2026;13(11):1319. doi:10.3390/bioengineering13111319

BibTeX
@article{Algl2026,
  author = {Algül, Hilal and Yıldız, Mahzun and Dinç, Eda Gürbüz and Dinç, Ferit and Orhan, Kaan and Altuğ, Ayşe Tuba},
  title = {Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {11},
  pages = {1319},
  doi = {10.3390/bioengineering13111319}
}
Kostenlos starten →