Intra-Session Repeatability of Static Pedobarometric Measurements: Analysis of Variability in Plantar Pressure Parameters and the Spatial Localization of the Center of Pressure and Peak Pressure
Bioengineering · 20.08.2026 · 13 (8) · 940
DOI: 10.3390/bioengineering13080940 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 20.08.2026. Verfasst von Lucia Bednarčíková und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Letná 1/9, 042 00 Košice, Sl…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Ministry of Education, Research, Development and Youth of the Slovak Republic, Cultural and Educational Grant Agency of the Ministry of Education, Science, Research and Sport of the Slovak Republic.
Abstract (Originalsprache)
Static pedobarometry is widely used to assess plantar pressure distribution and postural control; however, its clinical interpretation depends on measurement repeatability and reliability. The aim of our article is to evaluate the repeatability of plantar pressure parameters and the spatial localization of the center of pressure (CoP) and peak pressure (PP) during static bipedal standing. Five healthy adults underwent 30 repeated static measurements using the Sidas Press-Cam platform under standardized laboratory conditions. Analyzed parameters included contact area, mean pressure, peak pressure, and the center of pressure coordinates. Repeatability was assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland–Altman analysis. Contact area showed high single-measure repeatability (ICC (2, 1) = 0.90). Peak pressure and mean pressure demonstrated moderate repeatability for single trials but excellent repeatability when averaged (ICC (2, k) = 0.97–0.996). The center of pressure exhibited greater mediolateral than anteroposterior variability. Peak pressure localization remained stable within 3 SD and predominantly on the dominant limb. Averaging multiple trials enhances measurement repeatability, suggesting that repeated static pedobarometric assessments may provide more consistent estimates of plantar pressure parameters. However, these findings should be interpreted as preliminary evidence from an intra-session repeatability study due to the limited sample size.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Letná 1/9, 042 00 Košice, Slovakia.
- Department of Languages, Technical University of Košice, Letná 1/9, 042 00 Košice, Slovakia.
ORCID-Profile: Lucia Bednarčíková, Teodor Tóth, Patrícia Gajdošová
Förderung
- The Ministry of Education, Research, Development and Youth of the Slovak Republic
- Cultural and Educational Grant Agency of the Ministry of Education, Science, Research and Sport of the Slovak Republic
Zitieren
APA
Bednarčíková, L., Tóth, T., Michalíková, M., & Gajdošová, P. (2026). Intra-Session Repeatability of Static Pedobarometric Measurements: Analysis of Variability in Plantar Pressure Parameters and the Spatial Localization of the Center of Pressure and Peak Pressure. Bioengineering, 13(8), 940. https://doi.org/10.3390/bioengineering13080940
Vancouver
Bednarčíková L, Tóth T, Michalíková M, Gajdošová P. Intra-Session Repeatability of Static Pedobarometric Measurements: Analysis of Variability in Plantar Pressure Parameters and the Spatial Localization of the Center of Pressure and Peak Pressure. Bioengineering. 2026;13(8):940. doi:10.3390/bioengineering13080940
BibTeX
@article{Bednarkov2026,
author = {Bednarčíková, Lucia and Tóth, Teodor and Michalíková, Monika and Gajdošová, Patrícia},
title = {Intra-Session Repeatability of Static Pedobarometric Measurements: Analysis of Variability in Plantar Pressure Parameters and the Spatial Localization of the Center of Pressure and Peak Pressure},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {8},
pages = {940},
doi = {10.3390/bioengineering13080940}
}