EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Generalized Retinal Artery/Vein Segmentation via Multi-Dataset Fine-Tuning and Pathology Subgroup Analysis

Seo Gyeong Lee iD, Ju-Hyuck Han

Bioengineering · 30.07.2026 · 13 (8) · 882

DOI: 10.3390/bioengineering13080882 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 30.07.2026. Verfasst von Seo Gyeong Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical IT Engineering, Konyang University, 158 Gwanjeodong-ro, Seo-gu, Daejeon 35365, Republic of Korea. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Daejeon RISE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Automatic artery/vein (A/V) segmentation in color fundus photography underpins retinal biomarkers such as the arteriolar-to-venular ratio (AVR), yet single-dataset models generalize poorly across institutions and pathologies.

Methods

Using pre-trained Recursive Refinement W-Net (RRWNet) weights as initialization, eight heterogeneous datasets were jointly fine-tuned under a single set of weights for 50 epochs: five A/V-labeled (Fundus-AVSeg, LES-AV, RITE, FIREFLY-Gen, PSEUDO_AV) and three vessel-only (DRIVE, CHASE_DB1, HRF). A vessel-only loss separation strategy applied only the vessel-channel loss to vessel-only datasets, preventing A/V metric dilution; post-processing combined field-of-view masking, connected-component denoising, and morphological refinement, outputting artery, vein, and vessel masks with crossing and junction maps.

Results

Loss separation recovered validation DSC from 0.518 to 0.570 (AUC up to 0.959). On re-inference across four datasets (332 images), the single-weight model attained mean-AV DSC 0.657 ± 0.085 and AUC 0.976 ± 0.016; across normal, AMD, glaucoma, and DR subgroups, performance was statistically indistinguishable (Kruskal–Wallis, all p > 0.36), indicating consistent behavior across pathologies.

Conclusions

Within a leakage-aware internal evaluation, the single-weight model produced stable A/V segmentation across the four datasets and across pathology subgroups, indicating preliminary internal consistency rather than proven cross-domain generalization. Because the evaluation reuses data seen during training and no external or patient-level held-out set was used, robustness claims are deferred; leakage-free external validation and patient-level re-evaluation are identified as the essential next steps.

Schlagwörter

Stichwörter der Autor:innen

artery–vein classificationcolor fundus photographyconvolutional neural networksdeep learningdomain generalizationimage segmentationretinal imaging

Autor:innen und Institutionen

  • Department of Medical IT Engineering, Konyang University, 158 Gwanjeodong-ro, Seo-gu, Daejeon 35365, Republic of Korea.

ORCID-Profile: Seo Gyeong Lee

Förderung

  • Daejeon RISE

Zitieren

APA

Lee, S. G., & Han, J. H. (2026). Generalized Retinal Artery/Vein Segmentation via Multi-Dataset Fine-Tuning and Pathology Subgroup Analysis. Bioengineering, 13(8), 882. https://doi.org/10.3390/bioengineering13080882

Vancouver

Lee SG, Han JH. Generalized Retinal Artery/Vein Segmentation via Multi-Dataset Fine-Tuning and Pathology Subgroup Analysis. Bioengineering. 2026;13(8):882. doi:10.3390/bioengineering13080882

BibTeX
@article{Lee2026,
  author = {Lee, Seo Gyeong and Han, Ju-Hyuck},
  title = {Generalized Retinal Artery/Vein Segmentation via Multi-Dataset Fine-Tuning and Pathology Subgroup Analysis},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {8},
  pages = {882},
  doi = {10.3390/bioengineering13080882}
}
Kostenlos starten →