A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study
Bioengineering · 25.07.2026 · 13 (8) · 861
DOI: 10.3390/bioengineering13080861 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 25.07.2026. Verfasst von Jun Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Research Center, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shenzhen Science and Technology Innovation Commission, Guangdong Basic and Applied Basic Research Foundation, Natural Science Foundation of Guangdong Province, China.
Abstract (Originalsprache)
Cerebrovascular computational fluid dynamics (CFD) models often rely on generic boundary conditions, which may limit their ability to represent subject-specific hemodynamics and cerebral autoregulation (CA). We propose a multimodal data-driven boundary calibration (MDBC) framework integrating transcranial color-coded Doppler and continuous blood pressure monitoring to optimize individualized outlet resistances. As a proof-of-concept, we evaluated the MDBC framework in a single healthy volunteer at resting baseline and enhanced external counterpulsation (EECP)—a hemodynamic perturbation potentially triggering CA. Compared with conventional open boundary (OB) and static Murray allocation boundary (SMAB) strategies, MDBC achieved closer agreement with in vivo middle cerebral artery (MCA) velocity waveforms under both states. At rest, MDBC’s left MCA relative root mean square error (rRMSE) was 7.19%, versus 22.85% (OB) and 30.89% (SMAB). During EECP, conventional models yielded rRMSEs > 32%, whereas MDBC maintained 11.24%. Meanwhile, MDBC reproduced inter-hemispheric perfusion imbalance, an EECP-induced flow surge in the right MCA, and pronounced wall shear stress increases that were masked by generic boundary strategies. Moreover, MDBC estimated a 25.8% increase in global cerebrovascular resistance during EECP, suggesting the capability of the framework to characterize subject-specific impedance adaptations potentially associated with CA during intervention. These single-subject findings support the technical feasibility of integrating multimodal physiological measurements into cerebrovascular CFD boundary calibration and warrant further validation in larger cohorts and patient populations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Research Center, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China.
- School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China.
- Department of Ultrasound, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China.
- Department of Urology, Shenzhen Futian Second People's Hospital, Shenzhen 518033, China.
- Department of Neurosurgery, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China.
- National Health Commission (NHC) Key Laboratory of Assisted Circulation, Sun Yat-sen University, Guangzhou 510080, China.
Förderung
- Shenzhen Science and Technology Innovation Commission
- Guangdong Basic and Applied Basic Research Foundation
- Natural Science Foundation of Guangdong Province, China
Zitieren
APA
Hu, J., Li, H., Shen, X., Zhong, Y., Zheng, H., Liu, Y., Luo, B., & Du, J. (2026). A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study. Bioengineering, 13(8), 861. https://doi.org/10.3390/bioengineering13080861
Vancouver
Hu J, Li H, Shen X, Zhong Y, Zheng H, Liu Y, et al. A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study. Bioengineering. 2026;13(8):861. doi:10.3390/bioengineering13080861
BibTeX
@article{Hu2026,
author = {Hu, Jun and Li, Hongye and Shen, Xuelian and Zhong, Yonghao and Zheng, Hanxiong and Liu, Yiao and Luo, Bin and Du, Jianhang},
title = {A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {8},
pages = {861},
doi = {10.3390/bioengineering13080861}
}
EUVIMED