Fachartikel in der Zeitschrift Bioengineering, online erschienen am 17.07.2026. Verfasst von Rina Aoyama und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Showa Medical University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8666, Japan. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cabinet Office, Japan Society for the Promotion of Science, Japan Science and Technology Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Total anomalous pulmonary venous connection (TAPVC) is a severe congenital heart disease, yet its prenatal detection rate remains suboptimal. To support prenatal ultrasound screening of TAPVC, the post-left atrium space (PLAS) index and the left-atrial posterior-space-to-diagonal (LAPSD) ratio measured in the four-chamber view (4CV) have been proposed as useful biometric parameters. In this study, we developed a novel approach that integrates automated 4CV extraction (AE) from fetal cardiac ultrasound videos with automated measurement of these indices. The heart, crux, and descending aorta were segmented using DeepLabv3+, UNet3+, and SegFormer. The screening performance of the AE-based methods was comparable to that of manual 4CV extraction, as demonstrated by similar mean areas under the receiver operating characteristic curve (AUCs). In a clinical comparison study, the mean AUC values for residents, fellows, experts, AE-DeepLabv3+, AE-UNet3+, and AE-SegFormer were 0.784, 0.801, 0.996, 0.903, 0.928, and 0.940, respectively, for the PLAS index and 0.797, 0.801, 0.996, 0.919, 0.916, and 0.940, respectively, for the LAPSD ratio. Although experts demonstrated the best overall performance, the fully automated methods consistently outperformed both the residents and fellows. This approach may support less experienced examiners, improve screening accuracy, streamline clinical workflows, and ultimately enhance the prenatal detection of TAPVC.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencefetal echocardiographyleft-atrial posterior-space-to-diagonal ratiopost-left atrium space indexprenatal ultrasound screeningtotal anomalous pulmonary venous connection

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Showa Medical University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8666, Japan.
  • Department of NCC Cancer Science, Biomedical Science and Engineering Track, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
  • Division of Medical AI Research and Development, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
  • Digital Health Platform Development Office, Healthcare Business Unit, Fujitsu Japan Ltd., 1-5 Omiya-cho, Saiwai-ku, Kawasaki 212-0014, Japan.
  • AI Medical Engineering Team, RIKEN Center for Advanced Intelligence Project, 1-4-1 Nihonbashi, Chuo-ku, Tokyo 103-0027, Japan.

ORCID-Profile: Masaaki Komatsu, Reina Komatsu, Katsuji Takeda, Naoki Teraya, Ken Asada, Syuzo Kaneko, Ryu Matsuoka, Akihiko Sekizawa, Ryuji Hamamoto

Förderung

  • Cabinet Office
  • Japan Society for the Promotion of Science
  • Japan Science and Technology Agency
  • Ministry of Education, Culture, Sports, Science and Technology
  • National Cancer Centre Japan
  • Cabinet Office BRIDGE Program for Bridging the Gap Between R&D and the Ideal Society
  • Generating Economic and Social Value
  • JST SPRING

Zitieren

APA

Aoyama, R., Harada, N., Komatsu, M., Komatsu, R., Takeda, K., Teraya, N., Asada, K., Kaneko, S., Iwamoto, K., Matsuoka, R., Sekizawa, A., & Hamamoto, R. (2026). Fully Automated Biometric Parameter Measurement in Prenatal Ultrasound Screening for Total Anomalous Pulmonary Venous Connection. Bioengineering, 13(7), 822. https://doi.org/10.3390/bioengineering13070822

Vancouver

Aoyama R, Harada N, Komatsu M, Komatsu R, Takeda K, Teraya N, et al. Fully Automated Biometric Parameter Measurement in Prenatal Ultrasound Screening for Total Anomalous Pulmonary Venous Connection. Bioengineering. 2026;13(7):822. doi:10.3390/bioengineering13070822

BibTeX
@article{Aoyama2026,
  author = {Aoyama, Rina and Harada, Naoaki and Komatsu, Masaaki and Komatsu, Reina and Takeda, Katsuji and Teraya, Naoki and Asada, Ken and Kaneko, Syuzo and Iwamoto, Kazuki and Matsuoka, Ryu and Sekizawa, Akihiko and Hamamoto, Ryuji},
  title = {Fully Automated Biometric Parameter Measurement in Prenatal Ultrasound Screening for Total Anomalous Pulmonary Venous Connection},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {7},
  pages = {822},
  doi = {10.3390/bioengineering13070822}
}
Kostenlos starten →