Angle-Matched Isometric and Isokinetic Hamstring-to-Quadriceps Ratios Are Not Directly Interchangeable: An Exploratory Multi-Angle Dynamometry Study
Bioengineering · 26.06.2026 · 13 (7) · 744
DOI: 10.3390/bioengineering13070744 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 26.06.2026. Verfasst von Zhaoxiang Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School, Gdańsk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdańsk, Poland. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Hamstring-to-quadriceps (H/Q) strength ratios describe knee flexor-to-extensor torque balance, but their interpretation may depend on joint angle, contraction mode, and denominator stability. This exploratory repeated-measures study examined whether angle-matched H/Q ratios obtained from isometric and isokinetic dynamometry are directly interchangeable. Fourteen healthy young adults performed maximal knee extension and flexion using a Biodex System 4 Pro. Isometric testing was conducted at 10°, 30°, 60°, 90°, and 110° of knee flexion; isokinetic testing was performed at 60°/s, 150°/s, and 300°/s, with torque extracted at matched angles. H/Q ratios were calculated as flexor torque divided by extensor torque for each angle, limb, and mode and analyzed after log transformation. In the all-angle model, log-transformed H/Q ratio showed a significant angle effect (F(4,52) = 14.60, p < 0.001, partial η2 = 0.529), limb effect (F(1,13) = 5.54, p = 0.035, partial η2 = 0.299), angle × mode interaction (F(12,156) = 2.78, p = 0.002, partial η2 = 0.176), and angle × mode × limb interaction (F(12,156) = 2.60, p = 0.004, partial η2 = 0.167). After excluding endpoint angles, the angle × mode interaction remained significant (F(6,78) = 8.60, p < 0.001, partial η2 = 0.398). These findings suggest that angle-specific H/Q ratios are influenced by joint position and testing mode. Because of the small sample and absence of protocol-specific test-retest reliability, the results should be interpreted as exploratory and hypothesis-generating. Isometric and isokinetic H/Q ratios should not be treated as directly interchangeable, and endpoint ratios should be interpreted together with the underlying flexor and extensor torque values.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doctoral School, Gdańsk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdańsk, Poland.
- Faculty of Physical Culture, Gdańsk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdańsk, Poland.
ORCID-Profile: Piotr Aschenbrenner
Zitieren
APA
Zhang, Z., Bocian, P., & Aschenbrenner, P. (2026). Angle-Matched Isometric and Isokinetic Hamstring-to-Quadriceps Ratios Are Not Directly Interchangeable: An Exploratory Multi-Angle Dynamometry Study. Bioengineering, 13(7), 744. https://doi.org/10.3390/bioengineering13070744
Vancouver
Zhang Z, Bocian P, Aschenbrenner P. Angle-Matched Isometric and Isokinetic Hamstring-to-Quadriceps Ratios Are Not Directly Interchangeable: An Exploratory Multi-Angle Dynamometry Study. Bioengineering. 2026;13(7):744. doi:10.3390/bioengineering13070744
BibTeX
@article{Zhang2026,
author = {Zhang, Zhaoxiang and Bocian, Patrycja and Aschenbrenner, Piotr},
title = {Angle-Matched Isometric and Isokinetic Hamstring-to-Quadriceps Ratios Are Not Directly Interchangeable: An Exploratory Multi-Angle Dynamometry Study},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {7},
pages = {744},
doi = {10.3390/bioengineering13070744}
}
EUVIMED