Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design
Bioengineering · 30.03.2026 · 13 (4) · 401
DOI: 10.3390/bioengineering13040401 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 30.03.2026. Verfasst von Edward Matjeka und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical, Bioresources, and Biomedical Engineering, University of South Africa, Pretoria 0002, South Africa. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Development of technology for the design of numerical modeling and additive manufacturing of mesh structures for transcatheter implantation of the aortic valve.
Abstract (Originalsprache)
To design novel heart valve bioprostheses, it is extremely important to predict leaflet failure and fatigue for 10–20 years, as the aortic valve opens and closes approximately 40 million times per year. Most studies devoted to aortic valve leaflets mechanical tests employ uniaxial or biaxial tests, which do not fully and explicitly describe the time-dependent biomechanical behavior of this tissue. The aim of this study was to evaluate the viscoelastic response of porcine pericardium using biaxial tensile tests. Biaxial creep tests were performed on a biaxial test machine to evaluate the circumferential and axial behavior of the porcine pericardium under creep testing, and biaxial stress relaxation was used to complement creep. The results showed that the creep behavior was the same in both directions after 1 s, 60 s, 300 s, 900 s, and 1800 s. After 30 min of creep, deformation in the circumferential and radial directions was 3303 × 10−6 and 5192.9 × 10−6, respectively. Stress relaxation tests showed the same behavior as creep. At stress relaxation test after 30 min, the pericardium deformation in the circumferential and radial directions was 15.28 kPa and 9.6 kPa, respectively. The Prony series with Levenberg–Marquardt as the optimizer was used to obtain material parameters to use for finite element analysis. The data obtained during such tests can be employed in numerical FSI simulations of novel aortic valve bioprosthesis long-term performance in a patient’s body.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical, Bioresources, and Biomedical Engineering, University of South Africa, Pretoria 0002, South Africa.
- Research Center for Genetics and Life Sciences, Sirius University of Science and Technology, Sirius 354340, Russia.
- Biofluids Laboratory, Perm National Research Polytechnic University, Perm 614990, Russia.
- Department of Mechanical Engineering, Faculty of Engineering and the Built Environment, Durban University of Durban, Durban 4001, South Africa.
ORCID-Profile: Edward Matjeka, Alex G Kuchumov, Harry M Ngwangwa, Thanyani Pandelani, Fulufhelo Nemavhola
Förderung
- Development of technology for the design of numerical modeling and additive manufacturing of mesh structures for transcatheter implantation of the aortic valve
Zitieren
APA
Matjeka, E., Kuchumov, A. G., Ngwangwa, H. M., Pandelani, T., & Nemavhola, F. (2026). Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design. Bioengineering, 13(4), 401. https://doi.org/10.3390/bioengineering13040401
Vancouver
Matjeka E, Kuchumov AG, Ngwangwa HM, Pandelani T, Nemavhola F. Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design. Bioengineering. 2026;13(4):401. doi:10.3390/bioengineering13040401
BibTeX
@article{Matjeka2026,
author = {Matjeka, Edward and Kuchumov, Alex G and Ngwangwa, Harry M and Pandelani, Thanyani and Nemavhola, Fulufhelo},
title = {Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {4},
pages = {401},
doi = {10.3390/bioengineering13040401}
}