Fachartikel in der Zeitschrift Bioengineering, online erschienen am 20.03.2026. Verfasst von Ádám Vörös und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Technology, Széchenyi István University, 9026 Győr, Hungary. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cooperative Doctoral Program (EKÖP-KDP).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Custom-made subperiosteal implants are increasingly used in clinical cases where significant bone loss due to trauma or disease renders conventional endosseous implant placement unfeasible. This study investigated how different internal structural designs affect the deformation and stress distribution in mandibular subperiosteal implants under clinically relevant loading conditions. An idealized implant geometry was defined based on average human mandibular dimensions, and four configurations with identical outer shape and connection features were created, differing only in sidewall architecture (solid, top-relieved, top-relieved with lateral perforations, and top-relieved lattice framework). All specimens were manufactured by metal additive manufacturing and evaluated using cone-beam computed tomography (CBCT). Mechanical testing was performed in two stages: (i) cyclic loading consisting of 500 bite cycles at an overall force of ~326–350 N and (ii) a single static high-load event of 2000 N, applied parallel to the fixation pin axes. CT datasets acquired before and after each stage were compared to detect permanent deformation. No measurable residual deformation was identified in any configuration; the only observed macroscopic change was an adhesive-bond limitation in one case, rather than structural yielding of the implant. Finite element analysis further supported these findings by identifying localized stress concentrations mainly at the implant–prosthetic interface and by revealing the load-transfer zones that govern the mechanical response. Overall, the results indicate that lightweight, perforated, and lattice-based internal designs can preserve global structural integrity across physiological and supra-physiological load ranges while enabling design optimization to improve stress distribution.

Schlagwörter

Stichwörter der Autor:innen

additive manufacturingcomputed tomographyfinite element analysisimplant deformationlattice structuresmandibular implantsubperiosteal implant

Autor:innen und Institutionen

  • Department of Materials Science and Technology, Széchenyi István University, 9026 Győr, Hungary.
  • Dent Art Technik Kft., 9024 Győr, Hungary.

ORCID-Profile: Ádám Vörös, Ibolya Zsoldos

Förderung

  • Cooperative Doctoral Program (EKÖP-KDP)

Zitieren

APA

Vörös, Á., Lőrincz, B., Kónya, J., & Zsoldos, I. (2026). Effect of Internal Structural Design on Stress Distribution in 3D-Printed Subperiosteal Implants Under Mechanical Loading. Bioengineering, 13(3), 368. https://doi.org/10.3390/bioengineering13030368

Vancouver

Vörös Á, Lőrincz B, Kónya J, Zsoldos I. Effect of Internal Structural Design on Stress Distribution in 3D-Printed Subperiosteal Implants Under Mechanical Loading. Bioengineering. 2026;13(3):368. doi:10.3390/bioengineering13030368

BibTeX
@article{Vrs2026,
  author = {Vörös, Ádám and Lőrincz, Balázs and Kónya, János and Zsoldos, Ibolya},
  title = {Effect of Internal Structural Design on Stress Distribution in 3D-Printed Subperiosteal Implants Under Mechanical Loading},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {3},
  pages = {368},
  doi = {10.3390/bioengineering13030368}
}
Kostenlos starten →