The Effect of Thermocycling on the Microhardness of Contemporary Glass Ionomer-Based Restorative Materials: An In Vitro Study
Bioengineering · 29.01.2026 · 13 (2) · 161
DOI: 10.3390/bioengineering13020161 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 29.01.2026. Verfasst von Enes Bardakci und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Dentistry, Harran University Faculty of Dentistry, Sanliurfa 63050, Turkey. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Glass ionomer-based restorative materials are widely used in pediatric dentistry because of their chemical adhesion to tooth structure, ion-releasing capacity, and clinical handling advantages; however, their mechanical durability under simulated oral aging conditions remains a critical factor influencing long-term clinical performance. This in vitro study aimed to evaluate and compare the surface microhardness of three contemporary glass ionomer-based restorative materials—Beautifil Bulk Restorative, EQUIA Forte HT, and Fuji II LC—before and after thermocycling. A total of 90 disc-shaped specimens (10 mm in diameter and 2 mm in thickness) were prepared, with 30 samples allocated to each material group. Microhardness measurements were performed using the Vickers hardness test at baseline and after 10,000 thermocycling cycles between 5 °C and 55 °C to simulate intraoral aging. Results were expressed as the mean ± standard deviation, and statistical analyses were conducted using non-parametric tests. Thermocycling resulted in a statistically significant reduction in microhardness values for all tested materials (p < 0.05). Beautifil Bulk Restorative exhibited the highest microhardness values both before and after thermocycling, followed by Fuji II LC and EQUIA Forte HT, with significant differences observed among all groups (p < 0.001). Within the limitations of this study, Beautifil Bulk Restorative may be considered a favorable option for restorations in young permanent teeth, whereas EQUIA Forte HT, exhibiting lower microhardness values, may be more suitable for primary teeth, where physiological wear is expected.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Dentistry, Harran University Faculty of Dentistry, Sanliurfa 63050, Turkey.
- Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, CA 94103, USA.
- Department of Pediatric Dentistry, Dicle University Faculty of Dentistry, Diyarbakır 21280, Turkey.
ORCID-Profile: Enes Bardakci, Didem Ozdemir Ozenen, Izzet Yavuz
Zitieren
APA
Bardakci, E., Ozdemir Ozenen, D., & Yavuz, I. (2026). The Effect of Thermocycling on the Microhardness of Contemporary Glass Ionomer-Based Restorative Materials: An In Vitro Study. Bioengineering, 13(2), 161. https://doi.org/10.3390/bioengineering13020161
Vancouver
Bardakci E, Ozdemir Ozenen D, Yavuz I. The Effect of Thermocycling on the Microhardness of Contemporary Glass Ionomer-Based Restorative Materials: An In Vitro Study. Bioengineering. 2026;13(2):161. doi:10.3390/bioengineering13020161
BibTeX
@article{Bardakci2026,
author = {Bardakci, Enes and Ozdemir Ozenen, Didem and Yavuz, Izzet},
title = {The Effect of Thermocycling on the Microhardness of Contemporary Glass Ionomer-Based Restorative Materials: An In Vitro Study},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {2},
pages = {161},
doi = {10.3390/bioengineering13020161}
}
EUVIMED