The Impact of Stenosis Severity on Hemodynamic Parameters in the Iliac Artery: A Fluid–Structure Interaction Study
Bioengineering · 28.09.2025 · 12 (10) · 1042
DOI: 10.3390/bioengineering12101042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 28.09.2025. Verfasst von Nima Rahmati und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran 19991-43344, Iran. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The common iliac artery supplies blood to the lower extremities, and stenosis in this region severely impacts hemodynamics. This study investigates the effects of 25%, 50%, and 75% iliac artery stenosis on key hemodynamic parameters using a fluid–structure interaction (FSI) approach. Semi-idealized geometries reconstructed from patient-specific data modeled realistic arterial behavior. Parameters such as wall displacement, time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), high oscillatory low shear magnitude (HOLMES) index, and endothelial cell activation potential (ECAP) were evaluated. Results showed peak wall displacement of 2.85 mm in the bifurcation zone under 75% stenosis. TAWSS increased with stenosis severity, peaking in stenotic regions and decreasing significantly downstream. OSI was highest in non-stenosed right branches and bifurcation areas, indicating multidirectional shear forces. HOLMES values were lowest downstream of stenoses, indicating disturbed flow. ECAP exceeded the thrombosis risk threshold (1.4 Pa−1) in post-stenotic zones under 75% stenosis, suggesting a higher risk of clot formation. These results demonstrate that stenosis disrupts local flow and causes hemodynamic changes downstream, emphasizing the need for comprehensive clinical assessment beyond the stenotic site. Regions with elevated ECAP and low HOLMES downstream may be prone to thrombosis, highlighting the importance of careful hemodynamic monitoring for treatment strategies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran 19991-43344, Iran.
- Cardiovascular Imaging Department, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran 19956-14331, Iran.
- Vascular Disease and Thrombosis Research Center, Rajaie Cardiovascular Institute, Tehran 19956-14331, Iran.
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
- Centre for Sustainable Business, International Business University, Toronto, ON M5S 2V1, Canada.
- Balsillie School of International Affairs (BSIA), Waterloo, ON N2L 6C2, Canada.
ORCID-Profile: Nima Rahmati, Hamidreza Pouraliakbar, Kian Javari, Alireza Jabbarinick, Parham Sadeghipour
Zitieren
APA
Rahmati, N., Pouraliakbar, H., Eskandari, A., Javari, K., Jabbarinick, A., Sadeghipour, P., Soltani, M., & Alimohammadi, M. (2025). The Impact of Stenosis Severity on Hemodynamic Parameters in the Iliac Artery: A Fluid–Structure Interaction Study. Bioengineering, 12(10), 1042. https://doi.org/10.3390/bioengineering12101042
Vancouver
Rahmati N, Pouraliakbar H, Eskandari A, Javari K, Jabbarinick A, Sadeghipour P, et al. The Impact of Stenosis Severity on Hemodynamic Parameters in the Iliac Artery: A Fluid–Structure Interaction Study. Bioengineering. 2025;12(10):1042. doi:10.3390/bioengineering12101042
BibTeX
@article{Rahmati2025,
author = {Rahmati, Nima and Pouraliakbar, Hamidreza and Eskandari, Arshia and Javari, Kian and Jabbarinick, Alireza and Sadeghipour, Parham and Soltani, Madjid and Alimohammadi, Mona},
title = {The Impact of Stenosis Severity on Hemodynamic Parameters in the Iliac Artery: A Fluid–Structure Interaction Study},
journal = {Bioengineering},
year = {2025},
volume = {12},
number = {10},
pages = {1042},
doi = {10.3390/bioengineering12101042}
}
EUVIMED